![VideoLogix PROTEUS Essential Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/videologix/proteus-essential/proteus-essential_user-manual_1015475032.webp)
32
Typical wiring connection for Quadrature Counters
Quadrature Counter 1
Quadrature Counter 2
Electrical Interface
A1
B1
RESET1
A2
B2
RESET2
Input compatibilty:
•
0-5V logic (10ma sink current)
•
Frequency < 10MHz
Power & ground can be provided to
the quadrature encoder via J55:
+5V
+3.3V
GND
Typical wiring connection for Simple Counters
Simple Counter 1
Simple Counter 2
Electrical Interface
Counter 1 pulse
RESET1
Counter 2 pulse
RESET2
Input compatibilty:
•
0-5V logic (10ma sink current)
•
Frequency < 1KHz (5msec debouce)