1. GOLDEN RULES - XL
1. Devices in Area 1 are
ALWAYS
subject to Entry and Exit delay.
2. If a Keypad or Badge Reader is entered into an Area, then all the devices in this Area are
also subject to Entry/Exit delays.
3. Never place the panel near an electric switchboard: there is a possibility of interference with
the Radio and GPRS modem.
4. Place the alarm panel at the most central location of the site to be protected. (guarantees a
better propagation of the radio)
5. Never record the same device twice without having first deleted the device off the panel.
6. Record a maximum of 19 peripheral devices and 19 User codes/badges (XL panels)
7. You are limited to 3 keypads or badge readers or combination there-of.
8. Installation height for Indoor MotionViewers is 2.1 to 2.35mtrs.
9. Installation height for Outdoor Motionviewers is 2
– 3mtrs. NOTE: Suited to protect assets
not areas, and should be angled down to cutoff the PIR view to10mtrs.
10. Never mount the keypad at the beginning of installation so that you can walk around with it
during programming.
11. Always clean the camera lens after installation (with a clean and dry piece of cloth, without
pressing on the lens)
12. The keypad becomes inactive after 30 seconds of inactivity, in order to make the display to
reappear, press on the [YES] key