INSTALL SHEET

ISMV 

STREAMING MOTIONVIEWER

Programming / RF Testing / Mounting

The following provides summarized steps for device 
programming,testing, and mounting. For complete details, 
refer to the control panel installation manual.

Loosen bottom screw          

   Separate base from ISMV 

Install 3 CR123A 3V batteries, observing correct polarity. 

Enter the panel into programming/configuration mode.

Using a programmed alphanumeric keypad, proceed through 

menus until the display shows ADD A NEW DEVICE.

5  

Press OK. The display shows PRESS PROGRAM BUTTON OF 

DEVICE.

Press and release the program button on the ISMV          using 

a paper clip. The ISMV LED flashes red         

.

 

Press OK, the keypad displays RADIO RANGE TEST ? Press 

OK again. The ISMV LED starts flashing and the keypad displays 
TEST IN PROGRESS.

Move the ISMV to the intended mounting location and 

confirm the signal is 9/9, indicating good communication with 
the control panel.            

Press OK to end the radio range test then press ESC/NO.

10 

The display shows : 

AREA ALLOCATION : 

AREA : 1

Press either arrow button on the keypad until the desired AREA 
number appears, then press OK. By default all devices in area 1 
will be subject to the entry and exit delays.

11

  The screen displays NAME + LOCATION : 

Enter an appropriate device name (up to 16 characters). The 
name of the device should describe its intended mounting 
location or zone. Press OK. The display will show the device 
number and name for your verification.

12  

Mount the ISMV on the wall:

Follow the mounting rules on page 1.

Hold the ISMV base against the mounting surface and mark 

the appropriate mounting holes.

Drill pilot holes and install anchors where needed.

>

 Place the base on mounting surface so that the pilot holes line 

up and secure base with appropriate screws.

Attach camera to base and secure with screw if required.

13 

Press OK. The display shows FUNCTIONAL DEVICE TEST? 

Press YES again and verify IMV operation. The red LED indicates 
the detection field.

14 

Press OK to end the detection test.

15 

The display shows ADD A NEW DEVICE? Repeat steps 1-14 

for remaining devices.

16  

When finished, exit from configuration mode by pressing 

and holding the ESC/NO for 5 seconds.

Wait for the keypad to display :  CAMERA  REGISTERED. 

2

1

3

3

4

4

1

2

Содержание ISMV 200

Страница 1: ...mming RF Testing Program detector and all other devices into the control panel and test RF communication at each intended device location to the control panel Mounting Mount detector at the tested location Mounting rules Use proper tools and hardware Mount indoors in a temperature controlled environment Mount camera 2 1m from the floor Respect Top and Bottom side of the Motion Viewer When possible...

Страница 2: ... AREA 1 Press either arrow button on the keypad until the desired AREA number appears then press OK By default all devices in area 1 will be subject to the entry and exit delays 11 The screen displays NAME LOCATION Enter an appropriate device name up to 16 characters The name of the device should describe its intended mounting location or zone Press OK The display will show the device number and n...

Страница 3: ... the ISMV in an angle to optimize detection It shall be mounted opposed to the access point or asset you need to protect The detector should not be mounted close to a door or an access point Such installation increase the probability of a missed intrusion When stairs mounted please aim the detector towards the entry or the exit of the stairwell Detection diagram Streaming option The new ISMV Motio...

Страница 4: ...65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body Cet équipement est conforme aux limites d exposition aux rayonnements IC établies pour un environnement non contrôlé Cet équipement doit être installé et utilisé avec un minimum de 2...

Страница 5: ...mera Angle 90 Sensor type CMOS Lighted video Programmable Color or B W Night vision video Black white automatic infrared Infrared illumination Automatic with 2 IR LEDs Infrared illumination distance 7m Video Video format H264 MPEG if not available Framerate 5 images per second Resolution QVGA 320x240 Video file size Up to 230 kB VIDEO PROPERTIES BOX Physical properties Material ABS UL94 V0 Install...

Отзывы: