Videofied Indoor Motion Viewer Скачать руководство пользователя страница 3

 

 

 

IMV Indoor Motion Viewer - Install sheet Ed05EN 

3

/

5

 

Indoor Motion Viewer IMV

 

I N ST AL L AT I O N   D AT A   S H E ET

 

Detection diagrams 

 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
Technical data subject to change without notice. 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2m 

 

 

4m 

 

 

6m 

 

 

8m 

 

 

10m 

 

 

12m 

 

 5m 

4m 

3m 

2m 

1m 

1m 

2m 

3m 

4m 

5m 

PIR angle = 

90° 

Camera angle = 

110° 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal distance 

Floor 

level 

 0m 

1m 

4m 

8m 

12m 

Mounting at 2m10 

Mounting at 2m30 

1m00 

Содержание Indoor Motion Viewer

Страница 1: ...ces in the following order Programming RF Testing program detector and all other devices into the control panel and test RF communication at each intended device location to the control panel Mounting mount detector at the tested location Mounting rules Use proper tools and hardware Mount indoors in a temperature controlled environment Mount camera 2 1 to 2 3 m 6 9 to 7 5 ft from the floor Respect...

Страница 2: ...l panel 9 9 Press YES to end radio range test then press Esc No 1 10 0 The display shows AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired AREA number appears then press Yes By default all devices in area 1 will be subject to the entry and exit delays 1 11 1 The display shows NAME LOCATION Enter appropriate device name up to 16 characters The name of the device should descr...

Страница 3: ...wer IMV INSTALLATION DATA SHEET Detection diagrams Technical data subject to change without notice 0 2m 4m 6m 8m 10m 12m 5m 4m 3m 2m 1m 0 1m 2m 3m 4m 5m PIR angle 90 Camera angle 110 Horizontal distance Floor level 0m 1m 4m 8m 12m Mounting at 2m10 Mounting at 2m30 1m00 ...

Страница 4: ... radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourag...

Страница 5: ...est Yes with LED indicator RF test Yes Installation Mounting Mounting height 2m10 to 2m30 6 9 to 7 5ft Mounting on wall On flat wall with 2x screws In corner with 2x screws Closing of the casing Closing by clip or with screw if required by local legislation Environmental and Physical properties Temperature 10 50 C 14 F 122 F Relative humidity 90 non condensed IP level IP30 IK04 Material ABS type U...

Отзывы: