Videofied IDC Series Скачать руководство пользователя страница 2

Pairing the detector

Using a programmed alphanumeric keypad, access to level 4.

To unlock and get access to the installer level 4, you need to successively enter TWO 

codes (in any order) :

•  INSTALLER CODE (entered during intial programming)

•  USER CODE (Level3): the user must authorize the installer to get access to the 

configuration of his panel.

Once in level 4, proceed through the menu to reach ADD A NEW DEVICE.

Loosen the bottom screw and separate the base from the IDC . Install 1 Duracell CR123 

3V Lithium battery, observing correct polarity. Press and release the program button  
on the IDC using your finger or a screw driver. The IDC red LED will flash until it is paired 
with the panel.

When linked with the panel, the keypad will display :

The IDC is now paired with your Videofied

® 

 panel. It now needs to be configured and tested.

Tue 29/10 

  11:23

DISARMED LVL:1

ACCESS LEVEL

1

ACCESS LEVEL

LEVEL : 1

ACCESS LEVEL

LEVEL : 4

OK 

or 

YES

OK 

or 

YES

OK 

or 

YES

BADGE OR CODE

ACCESS LEVEL

4

CONFIGURATION

GENERAL

PARAMETERS

OK 

or 

YES

AREAS AND

DEVICES

DEVICES

ADD A NEW

DEVICE

OK 

or 

YES

OK 

or 

YES

PRESS PROGRAM

BUTTON OF DEVICE

OK 

or 

YES

CONTACT (1 - 25)

RECORDED

Program Button

2

IDC 

INDOOR DOOR CONTACT

INSTALL SHEET

Содержание IDC Series

Страница 1: ...ontrolledenvironment Mount detector on frame and magnet assembly on movable opening door window Donotexceed20mm 6 8 gapbetweendetectorandmagnet Magnetspacermustbeusedtomatchmagnetheightwithdetector toensurecorrectalignmentandfunctionality Donotinstallproductonferromagneticsurfaces The Indoor Door Contact IDC 200 601 702 is a wireless door window contact designed for use with Videofied security sys...

Страница 2: ...V Lithium battery observing correct polarity Press and release the program button on the IDC using your finger or a screw driver The IDC red LED will flash until it is paired with the panel 5 When linked with the panel the keypad will display The IDC is now paired with your Videofied panel It now needs to be configured and tested Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 A...

Страница 3: ...sign the detector to one of the four available areas used for delay and partial arming purposes please refer to the Videofied panel installation manual for more details about the areas 3 Enter an appropriate device name and location up to 16 characters then accept The display shows the device number and name for confirmation 4 Choose whether your contact is a perimeter device or not A perimùeter d...

Страница 4: ...ada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux c...

Страница 5: ...TRICAL PROPERTIES BOX Physical properties Material ABS ULV0 Dimensions Body 95 x 25 8 x 22mm Magnet 64 x 15 x 10mm Spacer 64 x 15 x 11mm Weight 38 g without battery Shock water protection markings IP31 IK04 Installation Mounting Mounting support Non ferromagnetic surface ex wood Wall mounting body 2 screws Box sealing body 1 screw Wall mounting magnet 2 screws Environmental properties Operating te...

Страница 6: ... DETECTEUR D OUVERTURE A CONTACT Marque commerciale Videofied Référence produits blanc IDC 200 N de certification blanc 2123200004A0 Référence produits brun IDC 210 N de certification brun 2123200004B0 IDC 601 902 928MHz FHSS Canada IC RSS 210 Issue 8 USA FCC Part 15C FCC47 CFR Part 15 IMV 702 915 928MHz FHSS Australia C Tick AS NZ4268 IMD 800 902 907 5MHz 915 928MHz Brazil Este equipamento opera ...

Отзывы: