Battery bank
Loads
&
Chargers
Performing a zero current calibration
7.2. Alarm settings
Please note that the SmartShunt is not equipped with a buzzer or an alarm relay like the BMV series is. The generated alarms are
only visible on the VictronConnect App while connected to the SmartShunt or are used to send an alarm signal to a GX device.
7.2.1. SoC alarm setting
When enabled, the alarm will activate when the state of charge falls below the set
value for more than 10 seconds. The alarm will deactivate when the state of charge
rises above the clear value
Default Setting
Range
Disabled
Disabled/enabled
When enabled
Default Setting
Set value
1%
0 - 100%
1%
Clear value
2%
0 - 100%
1%
7.2.2. Low voltage alarm
When enabled, the alarm will activate when battery voltage falls below the set value for more than 10 seconds. The alarm will
deactivate when the battery voltage rises above the clear value.
Default setting
Range
Disabled
Disabled/Enabled
When enabled
Default setting
Set value
1.0 V
0 - 95.0 V
0.1 V
Clear value
1.1 V
0 - 95.0 V
0.1 V
7.2.3. High voltage alarm
When enabled, the alarm will activate when battery voltage rises above the set value for more than 10 seconds. The alarm will
deactivate when the battery voltage drops below the clear value.
Default setting
Range
Disabled
Disabled / Enabled
When enabled
Default setting
Manual - SmartShunt
Page 21
All features and settings