On / Off / Charger-only switch = On
The AC input voltage is switched through and the charger operates in float mode.
On / Off / Charger-only switch = On. PowerControl and PowerAssist:
The AC input is switched through and the charge current is zero.
The inverter is switched on and, in case of PowerAssist, assists the AC input by supplying
additional power to the load (see section 2.1).
On / Off / Charger-only switch = On. Energy Storage System (ESS):
The AC input voltage is switched through. The inverter is switched on and supplies power to the
load, or excess power to the mains.
Charger only
On / Off / Charger-only switch = Charger only
The AC input voltage is switched through and the charger operates in bulk or absorption mode.
On / Off / Charger-only switch = Charger only
The AC input is switched through and the charger operates in float or storage mode.
The MultiPlus will shut down if four abnormal events occur within 30 seconds. The MultiPlus can be reset by
switching to Off and then to On.