USING THE UNIT
Operation is simple, just keep it connected to the correct
power supply and the refrigerator will maintain the
internal temperature it has been set to. Keep the doors
and / or drawers closed as much as possible to avoid
unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
For best results, make certain the unit remains
powered and has achieved the desired set point
before loading it with product. Pull down time will
vary depending upon the type of unit and ambient
conditions
The temperature was set at the factory at 38
º
F, but
you can adjust it to your own selected temperature. 30
seconds after adjustment, the display automatically
reverts to showing the current temperature.
The Refrigerator will automatically defrost as needed,
there is no set time for defrost. Push and immediately
release the "melting" or defrost button for a manual
defrost.
Note: Holding the defrost button in too long will shut the
controller off.
The internal fan will be on whenever the appliance is
connected to power.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
If equipped with glass doors, holding the SC button in will
turn the cabinet light on or off.
Select
Defrost
Increase
Decrease
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed
Why
What to do
dEF
Unit is defrosting
Nothing. Normal operation.
Hi
Cabinet temperature too warm
Confirm doors or drawers are closed.
dOr
Door is open
Close door, if message does not
change, call for service.
LEA
Compressor run time too long
Check doors closed. If yes, call for
service.
E01, E02, E03, E04
Sensor unplugged or has failed
Call for service.