Victory VBC-480/POD Скачать руководство пользователя страница 2

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice. 

Victory R

Refrigeration, IInc.

Remote R

Roll-IIn B

Blast C

Chiller

CHARACTERISTICS

VBC-480

VBC-660

Capacity (lbs./90 mins.)

480 lbs

660 lbs

Width, Overall

57.95” 

57.95”

Depth, Overall 

92.7”

92.7”

Depth, Door Open 90º

120.25”

120.25”

Height with Floor

101.7”

101.7”

Height without Floor

98.2”

98.2”

Clear Door Width

27.5”

27.5”

Clear Door Height

73.8” 

73.8”

No. of Carts (Optional)

2

2

Cabinet Voltage

208-230/60/3

208-230/60/3

Feed Wires (with Ground)

Total Amperes 

20

20

Note: 

The self-contained refrigeration system is top mounted for the storage cycle only.  This avoids short cycling of the stand

alone condensing unit when in the +38°F storage mode. All roll-in models require remote refrigeration.

Crated D

Dimensions aand W

Weights

Height  

W

Width  

D

Depth  

W

Weight

VBC-480 72”

90.5”

59”

1158 lbs

VBC-660 72”

90.5”

59”

1158 lbs

†Shipped on 2 skids, each of this weight.  Add 110 lbs per roll-in rack ordered.

NOTE: If cabinet is located
directly against wall and/or
under low ceiling, a minimum
clearance of 12” is required.

Insulated floor adds 3.5” in
height.

We reserve the right to change
specifications and product
design without notice. Such 
revisions do not entitle the 
buyer to corresponding 
replacements for previously 
purchased equipment.

Storage R

Refrigeration D

Data

Refrigerant     C

Compressor        B

BTUH*

VBC-480

R-134a

.75 H.P.

4759

VBC-660

R-134a

.75 H.P.

4759

*BTUH @ 100

o

F. Ambient, +25

o

F. Evaporator

Remote B

Blast C

Chilling R

Refrigeration D

Data

R

Reeffrriiggeerraanntt   LLiiqquuiidd LLiinnee    S

Suuccttiioonn LLiinnee       B

BTTU

U//H

H*

*

S

Siizzee

S

Siizzee

     .5 (X2)

1.125 (X2)     60,000

VBC-660  R404

     .5 (X2)

1.125 (X2)     72,000

*BTUH @ 90

o

F. Ambient, +5

o

F. Evaporator

Dimensional tolerance ± .25” Metric dimensions (mm)

Top View

Front View Without Insulated Floor

Printed in U.S.A.      ©October 2007  

VBC480SS/1007/US

420234_VBC-480.qxp  11/13/2007  10:06 AM  Page 2

VBC-480  R404

A

A

N/A

(Hard Wiring Required)

N/A

(Hard Wiring Required)