SUNSET |
15
1. If the range hood or lights do not operate after
installation:
•
Check if the range hood has been plugged in,
make sure that all power has been turned back
ON, fused not blown and all electrical wiring
are properly connected.
•
Swap out light assembly to working ones to
determine whether it is caused by defective
bulbs.
2. The range hood vibrates when the blower is
on:
•
The range hood might not have been secured
properly on to the ceiling or wall.
• This can also happen if a small duct is used.
3. The blower or fan seems weak:
•
Check that the duct sized used is at least 6” .
Range hood WILL NOT function efficiently with
insufficient duct size. For example: Connecting
this hood to 4”or 5’ duct will reduce the suction
and create extra noise and vibrations. Check if
duct is clogged or if damper unit is not installed
correctly or opening properly. A tight mesh on
a side wall cap unit might also cause restriction
to the air flow.
4.
The lights work but the blower is not spinning
at all, is stuck or is rattling.
•
The blower might be jammed or scraping the
bottom due to shipping damage. Please con-
tact us immediately.
5. The hood is not venting out properly:
•
Reduce the number of elbows and length of
duct work. Check if all joints are properly con-
nected, sealed, and taped.
•
Make sure the power is on high speed for
heavy cooking.
NOTE:
For all other inquiries, please contact Victory Range Hoods.
TROUBLESHOOTING