background image

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice. 

Victory  Refrigeration,  Inc.

Roll-iin  Refrigerators  

CHARACTERISTICS

ONE SECTION 

TWO SECTION

THREE SECTION

Roll-In

Roll-Thru

Roll-In

Roll-Thru

Roll-In

Roll-Thru

Width, Overall

36 

1

/

2

36 

1

/

2

68 

7

/

8

68 

7

/

8

101 

1

/

4

77 

3

/

4

Depth, Overall (incl. handles)

35 

7

/

8

39 

3

/

8

35 

7

/

8

39 

3

/

8

35 

7

/

8

39 

3

/

8

Height, Overall 

84

84

84

84

84

84

Depth, Door(s) Open 90º

65 

1

/

4

98 

1

/

8

65 

1

/

4

98 

1

/

8

65 

1

/

4

84 

5

/

8

Depth Case Over Ramp

35 

1

/

2

38 

1

/

2

35 

1

/

2

38 

1

/

2

35 

1

/

2

38 

1

/

2

Clear Door Width

27 

3

/

4

27

3

/

4

27

3

/

4

27

3

/

4

27

3

/

4

27

3

/

4

Clear Full Door Height

65 

1

/

4

65 

1

/

4

65 

1

/

4

65 

1

/

4

65 

1

/

4

55 

1

/

4

Capacity Net (cubic feet)

33.6

36.2

67.2

72.4

100.9

75.9

No. of Full Doors

1

2

2

4

3

6

Cabinet Voltage

115/60/1

115/60/1 115/60/1

115/60/1 115/60/1 115/60/1

Feed Wires

2

2

2

2

3

2

Condensing Unit Voltage

115/60/1

115/60/1

115/60/1

115/60/1 208-230/60/1 208-230/60/1

Condensing Unit Size (HP)

1

/

3

1

/

2

1

/

2

1

/

2

3

/

4

3

/

4

Total Amperes

9.2

12.0

11.9

12.6

10.6

12.1

Crated dim. & wts.

Ht. Width Depth Cu.Ft. Lbs

One Section

87 41

3

/

4

44

3

/

4

94.1 450

Two Section

87 74

5

/

8

44

3

/

4

168.1 750

Three Section

87 107 44

3

/

4

241.1 1140

Approximate Roll-Thru weights, add 15%

FOR REMOTE MODELS

– Substitute an “R” for the “S” in suffix. For

example: Model RIS-1D-S7 (self-contained) would be RIS-1D-R7
remote cabinet. Air circulating fans, expansion valve and plasticized
coil are provided. Condensing units not supplied. The following units
are recommended with 

1

/

2

” O.D. Suction line, 

1

/

4

” O.D. Liquid line.

Dimensional tolerance ± 

1

/

4

”   Metric dimensions (MM)

REMOTE REFRIGERATION

Cond. Unit

BTUH

Cabinet

Amps

One Section

1

/

3

H.P.

2540

115/60/1

2.2

Two Section

1

/

2

H.P.

4400

115/60/1

3.0

Three Section

3

/

4

H.P.

5800

115/60/1

4.3

For Remote Roll-Thru–Consult factory

Copyright January 2004

Printed in U.S.A. 010423

PART OF 

AGA

FOODSERVICE GROUP

39.38

(1000)

31.25

(793)

35.88

(911)

36.50

(927)

84.00

(2133)

27.75

(705)

65.25

(1657)

.88

(22)

ELEC.
CONN.

ELEC.
CONN.

65.25

(1657)

.88

(22)

27.75

(705)

27.75

(705)

84.00

(2133)

68.88

(1749)

39.38

(1000)

35.88

(911)

63.62

(1616)

ELEC. 
CONN.

ELEC. 
CONN.

32.38

(822)

14.12

(358)

34.88

(873)

35.50 (902)

TO RAMP

27.75

(705)

27.75

(705)

27.75

(705)

.88

(22)

65.25

(1657)

101.25

(2571)

84.00

(2133)

39.38

(1000)

96.00

(2438)

35.88

(911)

ELEC. 
CONN.

ELEC. 
CONN.

ROLL-THRU MODELS

ROLL-IN MODELS

NOTE: 

If cabinet is located

directly against wall and/or

under low ceiling, a minimum

clearance of 2” is required.

We reserve the right to

change specifications and

product design without

notice. Such revisions do not

entitle the buyer to

corresponding changes,

improvements, additions or

replacements for previously

purchased equipment.

Отзывы: