background image

User Manual for FSA Freezers 

Victory

Rev. 10/20

Victory

10

This is a cord-connected unit, and must be connected to its own 

dedicated

 power supply. Check the dataplate on the 

machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.

Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to 
unsafe cabinet temperature when GFI device trips from moisture.

Power Cord

This 115 volt model is equipped with a cord and 5-15P or 
5-20P plug, depending upon model.

If the power cord becomes damaged, it must be replaced 
with the identical cord.

Follow All National and Local Codes 

This unit must be grounded. Do not use extension cords 
and do not disable or by-pass ground prong on electrical 
plug.

Initial Start Up

Plug the power cord into the proper power supply.

The cabinet will soon begin to blow warm air out of the 
top area, and cool air will flow from the inside blower.

The cabinet temperature has been set at the factory and 
should not need adjustment, however if it was changed, 
the standard setting is 0º F.

Cautions

Care must be taken whenever moving or servicing the 
unit. The refrigerant is contained in a sealed system, but if 
released it may be flammable.

After the cabinet has been installed, leveled, and cleaned 
as described above, refer to the following checklist:

 Check for proper electrical hook-up.

Cabinet MUST NOT SHARE A RECEPTACLE with another 
piece of equipment

 Check that all clearances are in line with the 
aforementioned guidelines.

 Check that cabinet is level.

* NOTE: Once the unit has been started and reaches proper 
storage temperatures, it may be loaded with product. For 
proper energy efficiency and airflow we recommend a 
minimum1” clearance between product and side walls, 4” 
clearance between product and ceiling, and 1” clearance 
from the bottom of the unit.

ELECTRICAL

5-15P Plug

5-20P Plug

Содержание FS-1D-S1-HC

Страница 1: ...INSTRUCTIONS for all Hydrocarbon FSA Freezer Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web victoryrefrigeration com 809 191A Rev B 10 29 2020 SEE BACK COVER...

Страница 2: ...rly register equipment may limit or void the warranty Victory reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding cha...

Страница 3: ...rs There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flam...

Страница 4: ...necessary to move the Freezer after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY below the...

Страница 5: ...bstitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be connect...

Страница 6: ...Glass 13 9 FS A 2D S1 EW PT HC 58 3 8 x 38 5 8 x 84 1 8 Full Solid 13 9 FS A 2D S1 EW PT HD HC 58 3 8 x 38 5 8 x 84 1 8 Half Solid 13 9 FS A 2D S1 EW PT HG HC 58 3 8 x 36 1 8 x 84 1 8 Half Glass 13 9...

Страница 7: ...ide 0 0 in at the right side Floor Load the floor on which the Freezer is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum...

Страница 8: ...or the following None of the threads on the leg or caster stem should be visible once screwed in 3 Thread the stem casters or legs into the 13 holes in the bottom of the cabinet Tighten by hand as muc...

Страница 9: ...ion bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4 cl...

Страница 10: ...he cabinet will soon begin to blow warm air out of the top area and cool air will flow from the inside blower The cabinet temperature has been set at the factory and should not need adjustment however...

Страница 11: ...to lower the temperature faster When on the refrigeration system is always operating at maximum The temperature was set at the factory at 0 F but you can adjust it to your own selected temperature See...

Страница 12: ...aporator Fan is connected to control relay The Evaporator Fan is off when the evaporator temperature is above 35 F or the door is opened The Evaporator Fan is connected to control relay RTN400 termina...

Страница 13: ...Defrost active Blinking Activated manually or from Digital input OFF Otherwise 3 Fans Permanently On Fans active OFF Otherwise 4 Reduced SET Economy Permanently On Energy saving active Blinking Reduc...

Страница 14: ...manual defrost Scrolls the menu items Decreases the values Long press 5 sec Starts deep cooling cycle Returns up one level with respect to the current menu Confirms the parameter value Accesses the m...

Страница 15: ...pad will beep when unlocked and normal key pad operations performed Setting the Operating Set Point To change the operating set point press and release the set button to enter the machine menu set wil...

Страница 16: ...the set button to display the value and use the up or down button to change the value Once the value has been selected use the escape button to confirm the new value and return the pervious menu level...

Страница 17: ...User Manual for FSA Freezers Victory Rev 10 20 Victory 17...

Страница 18: ...Att Afd HA1 PAO dAO OAO tA1 AH2 HIGH temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 AL2 LOW temperature 2 alarm ON Active Automatic SP2 Att Afd HA2 PAO dAO OAO tA2 EA External...

Страница 19: ...Rinse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related item...

Страница 20: ...and secure into the notch in the front right corner of the raised panel 5 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down to avoid...

Страница 21: ...ount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discolorati...

Страница 22: ...um Temp control stuck in open position Replace temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check s...

Страница 23: ...MUST be in an area free from flame or spark It must be near an opened window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration service A c...

Страница 24: ...7 9 HEATER SAFETY THERMAL SWITCH BLU BLACK WHITE ORG COMP RELAY 10 11 BRN BLK BLK WHT FASCIA HEATERS RED LIGHT RELAY 13 14 RED CABINET LIGHTS POWER SUPPLY 24VDC HIGH CURRENT DIODE WHT BLK GLASS DOOR H...

Страница 25: ...4 RED CABINET LIGHTS POWER SUPPLY 24VDC HIGH CURRENT DIODE WHT BLK GLASS DOOR HEATERS GLASS DOOR MODELS ONLY WHT COMPRESSOR DETAIL START RELAY 10 COMP CONDENSER FAN C R S 2 4 OL 1 R C S C HIGH PRESSUR...

Страница 26: ...the Owner s Manual adjustment of door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or c...

Страница 27: ...LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIONS...

Страница 28: ...________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name __________________________________________________...

Отзывы: