background image

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice. 

Victory  Refrigeration,  Inc.

Display  Refrigerators  

(Half Door Model)

CHARACTERISTICS

TWO SECTION

Reach-In

Pass-Thru

Width, Overall

52 

1

/

8

52 

1

/

8

Depth, Overall (incl. handles)

36 

1

/

8

39 

3

/

8

Height, Overall (incl. adj. legs)

84

84

Depth, Door(s) Open 90º

58 

1

/

8

84 

5

/

8

Clear Sliding Door Width

19 

1

/

2

19 

1

/

2

Clear Hinged Door Width

21

1

/

8

21

1

/

8

Clear Half Door Height

25 

3

/

8

25 

3

/

8

Capacity Net (cubic feet)

46.5

48.0

No. of Half Doors

4

8

No. of Shelves

6

6

Shelf Area (square feet)

36.0

36.0

Cabinet Voltage

115/60/1

115/60/1

Feed Wires

2

3

Condensing Unit Voltage

115/60/1

115/60/1

Condensing Unit Size (HP)

1

/

2

3

/

4

Total Amperes

12.0

10.9

Crated dim. & wts.

Ht. Width Depth Cu.Ft. Lbs

Two Section

87 63

5

/

8

44

3

/

4

143.3 605

Approximate Pass-Thru weights, add 15%

FOR REMOTE MODELS

– Substitute an “R” for the “S” in suffix. For

example: Model DRS-1D-S7-HD (self-contained) would be DRS-1D-
R7-HD remote cabinet. Air circulating fans, expansion valve and plas-
ticized coil are provided. Condensing units not supplied. The following
units are recommended with 

1

/

2

” O.D. Suction line, 

1

/

4

” O.D. Liquid

line.

Dimensional tolerance ± 

1

/

4

”   Metric dimensions (MM)

REMOTE REFRIGERATION

Cond. Unit

BTUH

Cabinet

Amps

Two Section

1

/

3

H.P.

4400

115/60/1

3.7

For Remote Pass-Thru–Consult factory

Copyright January 2004

Printed in U.S.A. 010417

PART OF 

AGA

FOODSERVICE GROUP

34.38

(873)

32.38

(822)

14.12

(358)

84.00

(2133)

52.13

(1323)

25.38

(644)

21.12

(536)

25.38

(644)

21.12

(536)

FRONT VIEW

SIDE VIEW

36.13

(918)

39.38

(1000)

ELEC.

CONN.

ELEC.

CONN.

PASS-THRU MODEL

REACH-IN MODEL

NOTE: 

If cabinet is located directly against

wall and/or under low ceiling, a minimum

clearance of 2” is required.

We reserve the right to change

specifications and product design

without notice. Such revisions do not

entitle the buyer to corresponding

changes, improvements, additions or

replacements for previously purchased

equipment.