User Manual for ACRS Air Curtain Refrigerators
Victory
Rev. 02/21
Victory
22
CONDENSER CLEANING
Keeping the condenser coil clean is critical to efficient
operation.
1. Unplug unit from power supply.
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
2. Remove 5 thumb screws and access grille at the
bottom front of the cabinet.
3. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the fins.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be cleaned
with coil cleaner and that should be left to an experienced
technician.
4. Place access grille back on cabinet and secure it with
the original 5 thumb screws.
Note: Air filters are not recommended as they restrict the
flow of cooling air.