The  ash  from  the  combustion  process  is  conducted  in  an  ashtray  underneath  the  combustion  chamber.  The  ashtray  must  be 
periodically cleaned by pouring in a metal container or by a vacuum cleaner, but only when the pellet stove is cold. 

Through built-in circulating pump position (J) of (Fig.2.1), hot water passes from the integral boiler to the heating system. The 
filling  and  emptying  of  the  heating  system  is  carried  out  via  a  shut-off  valve,  which  has  to  be  assembled  outside.  The  system 
pressure is controlled by a manometer, which has to be assembled outside. 

The pellet stove is designed to operate with a built-in closed expansion vessel (H) and a pressure valve. 

High efficiency and low emissions of the pellet stove is guaranteed by an electronic control system that manage the amount of 
the fuel, the flue gases conduction, supplying of the combustion air and operation of the circulating pump. The control panel of 
the control system is placed in the backside on the top panel of the pellet stove position (G) in (Fig.2). Through the control panel 
can visualize and manage all stages of the operation of the pellet stove. 

8.

 

Fuel. 

Pellet stove e designed and programmed to burn wood pellets. They have a cylindrical shape and they are made of compressed 
by a high-pressure timber, without adhesive and additive materials. The wood pellets are sold in packages weighing 15 kg, which 
facilitates their storage. Better combustion, the wood pellets must be stored in dry and ventilated area. Pellet stove is designed, 
developed, programmed and tested to operate with wood pellets class A1, according to EN plus and BS EN ISO 17225-2: 2014 
with the following parameters: 

Maximum diameter:  

Ø 6 mm 

Maximum length:  

25 mm 

Maximum moisture content:  

8 % 

Maximum ash content:  

0.5% 

Minimum calorific value:  

4300 ccal/kg 

Good quality wood pellets ensure good combustion and low emissions into the atmosphere. 

The use of wood pellets with a 

lower quality

 results in a need for more frequent cleaning of the combustion chamber, reducing 

heat output and efficiency. They are increasing the fuel consumption sensitively. Inadequate wood pellets can cause blockage of 
the auger and to stop the operation of the pellet stove. 

IF PELLET STOVE BLOCKED, THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED. 

Using  low  quality  wood  pellets  or  non-manufacturer  recommended  above  may  compromise  the  operation  of  the 
pellet stove and lead to termination of the warranty. Pellet stove should not be used to burn other types of fuels or 
materials. Invalid guarantee! 

9.

 

Appliance installation. 

Trained and competent technicians or companies must perform installing of the pellet stove and heating system! The 
manufacturer does not warrant the operation of the heating system, but for  pellet stove only. Qualified technicians 
should perform all activities  in inspection and repair of electrical components. Switch off the  pellet  stove from the 

grid-circuit before any inspection or repair! 

Refer to the regulations  valid for the country,  where will  be used  the  pellet  stove, if you do not  find the information you are 
interested in this instruction manual. 

Not recommended installing a pellet stove in rooms where there is mounted another heater. If it does, it must be equipped with 
a separate air duct. 

Compatibility with other devices: 

Pellet stove should not be installed in the same room in which there absorbers and / or devices that reduce ventilation in the 
room. 

Checking electrical connections: 

Pellet stove is equipped with a power cable to be connected to a voltage 230V / 50Hz. Changes exceeding by 10% the voltage 
can damage the appliance. Grid-circuit must comply with the provisions of the laws and requirements for grounding. According 
to the requirements for grid-circuit connection, pellet stove should be installed so as to ensure free access to the plug and socket 
(230V  /  50Hz).  According  to  the  safety  requirements  prohibited  the  room  in  which  is  mounted  pellet  stove  to  an  electrical 
installation  that  is  located  on  the  floor.  Lack  of  bonding  /  grounding  can  cause  damage  for  which  the  manufacturer  is  not 
responsible. 

Positioning: 

To operate well, the pellet  stove should be leveled. The floor on which is placed the  pellet  stove must be of non-combustible 
materials (concrete, terrazzo, marble, terracotta, etc.). 

Given the easy servicing and refueling, we recommend the following minimum free distance around the  pellet stove: 1000 mm 
in front, back and sides -500 mm, top -minimum 1000 mm. 

 

Содержание Vittoria B

Страница 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Страница 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Страница 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Страница 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Страница 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Страница 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Страница 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Страница 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Страница 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Страница 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Страница 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Страница 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Страница 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Страница 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Страница 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Страница 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Страница 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Страница 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Страница 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Страница 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Страница 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Страница 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Страница 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Страница 24: ...Victoria 05 Ltd 24...

Страница 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Страница 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Страница 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Отзывы: