background image

02.2020

 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet stove

VITTORIA В*

 

 

 

3

 

 

 

1.

 

Introduction. 

We congratulate you on the excellent choice! 

 Do not leave this instruction manual unread. Installation and operation of a pellet stove associated with various legal 
obligations,  which  are  explained  in  this  instruction  manual.  According  to  the  laws  and  regulations  for  safe  use  of 
appliances of this class, the purchaser and user of the pellet stove undertake using this instruction manual to inform 

themselves for the assembling and the right operation of the appliance. 

This  instruction  manual  is  provided  to  assist  you  and  the  team  that  will  install,  put  into  operation  and  service  pellet  stove. 
Technicians, who will carry out the above activities to the pellet stove, must be trained and competent. 

Pellet stove operated only by adult persons familiar with the instruction manual. Pellet stove is not intended for use by persons 
with limited physical, sensory or mental abilities or lack of experience and knowledge, unless they are instructed and supervised 
in the use of the appliance by a person responsible for their safety. 

Pellet stove is manufactured and tested in accordance with standards EN 14785, EN 60335-1, EN 60335-2-102, EN 55014-1, EN 
61000-6-1, EN 61000-6-3and meets the approved technical documentation. 

Failure to follow the instructions described in this manual can lead to damage and consequences for which the manufacturer is 
not responsible. 

2.

 

Safety Information. 

• 

Pellet stove must not run without water in the system and the pressure must not fall below 1 bar. If the system is used 

without water, the pellet stove can be damaged. 

• 

Pellet  stove  is  designed  to  heat  water  through  automated  burn  in  the  combustion  chamber  of  wood  pellets  with  a 

diameter of Ø 6 mm, class A1. 

• 

Warranty is voided by unauthorized use of combustible material. 

• 

The  risk  that  could  arise  from  non-compliance  of  this  instructions  manual  is  a  direct  contact  with  electric  parts 

(internal), contact with fire or hot surfaces. 

• 

Pellet  stove  is  equipped  with  safety  components  that  guarantee  automatically  lock  in  case  of  failure  of  any  of  its 

components. Safety components are activated without outside interference. 

• 

Necessary  for  the  proper  operating  of  the  pellet  stove  is  its  proper  installation  in  accordance  with  the  following 

instructions. 

• 

Fire door should not be opened during operation of the  pellet stove. The burning process is automated and does not 

require external intervention. 

• 

It is not allowed to burn the pellet stove if there are cracks in the glass. 

• 

Under no circumstances should not be allowed penetration of foreign substances in the firebox or hopper. 

• 

Do not use combustible materials to clean soot in the chimney. 

• 

Turn off the pellet stove from the grid-circuit before cleaning or servicing. 

• 

Use a vacuum cleaner to clean the combustion chamber and pellet fuel hopper only when pellet stove is cold. 

• 

Do not use water to clean the internal parts of the pellet stove. 

• 

ATTENTION!

 During operation, the pellet stove must not be touched by a child as its surface is hot. Danger of burns! 

• 

The handle of the pellet stove warms as much as the front panel, so it must be operated with a heat-resistant glove. 

 

During operation of the pellet stove flue pipes and fire door are hot. 

 

Before the first ignition, remove the color label for energy efficiency from the glass of the pellet stove. 

• 

Do not place flammable objects and liquids near the pellet stove. 

• 

NEVER

 use flammable liquids to burn the pellet stove. 

• 

Do not obstruct fresh air to enter the room where pellet stove is installed and through the holes on the pellet stove. 

• 

Do not soak pellet stove and do not touch electrical components with wet hands. 

• 

Do not mount any adapters to flue pipes and chimney. 

• 

To  operate  properly  and  safely,  pellet  stove  should  be  installed  in  a  room  that  is  fire-resistant  and  equipped  with 

everything needed (electricity, air exchange, vents). 

• 

The temperature of the room where it is installed the pellet stove must not be lower than 0˚C. 

• 

Use appropriate non-freezing additives for water in the system. 

• 

Make sure the temperature of the return water is not lower than 45˚C. 

• 

Rating label is placed on the back of the pellet stove. 

• 

Keep  this  instruction  manual,  warranty  card  and  purchase  invoice  in  good  condition,  as  will  be  necessary  in  any 

inquiries. 

In extinction, do not burn the pellet stove again before cleaning the combustion chamber! 

Содержание Vittoria B

Страница 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Страница 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Страница 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Страница 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Страница 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Страница 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Страница 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Страница 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Страница 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Страница 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Страница 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Страница 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Страница 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Страница 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Страница 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Страница 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Страница 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Страница 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Страница 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Страница 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Страница 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Страница 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Страница 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Страница 24: ...Victoria 05 Ltd 24...

Страница 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Страница 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Страница 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Отзывы: