Victoria-05 Ltd.
16
10.2.5. Service technician settings.
Types of settings for service technician (entered with
service technician password)
Parameter
Factory
settings
Temperature On
Here one can set the Water Temperature, which the
pump switches on at.
45
0
C
Hysteresis(2°C ÷10
°
C)
This is the thermal lag at which the pump will stop
operating. I.e. if it has been set ot switch on at 60°С, it will
stop at 55°С, if the hysteresis is 5°С.
3
0
C
Initial purge
In Initial Purge the duration of the operation of the smoke
fan can be set to 100% in seconds in the Start Mode.
60 sec.
Extinguished
In extinct fire one can set the duration for the smoke fan
to operate at 100 % in Clean Mode. This mode gets active
if the contol unit transfers to switch-off and extinction of
the fireplace!
600sec.
Period
Here one cans et the time from 100 to 1000 seconds, in
10 seconds. This setting is about how long it will take the
fireplace to launch cumulate residue clean.
The time to set should be the sumtotal of the operation of
the screw conveyor. This way one can calculate the
amount of pellets after which there should follow a
cleaning process!
100% Fan
How long an Interim Purge will last.
The time is set within the range of 2 to 100 seconds, in 1
second.
200 sec.
20 sec.
Restore the factory settings of the control unit.
Outputs
Test
It sets all outputs active simultaneously
Pump
Water Heater
Smoke Fan
Screw Conveyor
Ash Clean (Not applicable)
Rest of the outputs Test Transition (Not applicable).