MAINTENANCE
DANGER
• Before performing any
repair or maintenance,
disconnect the tool from
the electrical source
to prevent accidental
startup of tool.
Failure to do so could result in death or
serious personal injury.
Prior to the start of each shift make sure all tool
and roll sets are clean . Lubricate the tool at the
grease ports .
Always lubricate upper roll bearings and main
shaft bearings when rolls are changed by
utilizing the grease ports . Use a No . 2EP Lithium
based grease .
On a monthly basis, lubricate the gear motor
with a spray-type, heavy-duty open gear
lubricant .
HYDRAULIC SYSTEM
The level of hydraulic fluid should be checked
before operation and
must
be checked several
times per year, especially if the hydraulic pump
is not operating properly . Use a 20# oil in the
summer and a 10# oil in the winter .
Relieve pressure in the hydraulic system by
opening the hydraulic pump valve, then remove
the plug indicated above to add hydraulic fluid .
PS3210 PIPE STAND
Regular lubrication is required for the PS3210
Pipe Stand . On a weekly basis, apply a light
machine oil to the location shown above at each
universal ball unit . Work the light machine oil in
by rotating the universal ball units .
REPLACEMENT PARTS
Any replacement parts must be ordered from
Victaulic to ensure proper tool operation .
18
REV_E
TM-RG3210
/ Operating and Maintenance Instructions Manual
Содержание RG3210
Страница 2: ......