Reference
Designator
Functional
Name
Functional
Name
H15,
H14
+S,
–S
Sockets for +S and –S test points.
TP18,
TP19
AC SIG INJ
Can be used to inject the isolated signal of network analyzer for bode
plot measurement to measure the stability in Remote Sense operation
using VTM and PRM
H18,
H19
AC SIG INJ
Sockets for AC +/- test points.
TP30
IM
IM test point provides the kelvin connection to IM pin. Can be used to
measure the IM signal of the half VTM. IM can be used to monitor the
output current of the VTM. Available on half VTM boards only.
H27
IM
Socket for IM test point.
Test Points and Sockets Description (Cont.)