background image

Limitation of Warranties

Information in this document is believed to be accurate and reliable. HOWEVER, THIS INFORMATION 
IS PROVIDED “AS IS” AND WITHOUT ANY WARRANTIES, EXPRESSED OR IMPLIED, AS TO THE 
ACCURACY OR COMPLETENESS OF SUCH INFORMATION.  VICOR SHALL HAVE NO LIABILITY FOR THE 
CONSEQUENCES OF USE OF SUCH INFORMATION.  IN NO EVENT SHALL VICOR BE LIABLE FOR ANY 
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT 
LIMITATION, LOST PROFITS OR SAVINGS, BUSINESS INTERRUPTION, COSTS RELATED TO THE REMOVAL 
OR REPLACEMENT OF ANY PRODUCTS OR REWORK CHARGES).

Vicor reserves the right to make changes to information published in this document, at any time 
and without notice. You should verify that this document and information is current. This document 
supersedes and replaces all prior versions of this publication.  

All guidance and content herein are for illustrative purposes only. Vicor makes no representation or 
warranty that the products and/or services described herein will be suitable for the specified use without 
further testing or modification. You are responsible for the design and operation of your applications 
and products using Vicor products, and Vicor accepts no liability for any assistance with applications or 
customer product design. It is your sole responsibility to determine whether the Vicor product is suitable 
and fit for your applications and products, and to implement adequate design, testing and operating 
safeguards for your planned application(s) and use(s). 

VICOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT, 
LIFE-CRITICAL OR SAFETY-CRITICAL SYSTEMS OR EQUIPMENT. VICOR PRODUCTS ARE NOT CERTIFIED 
TO MEET ISO 13485 FOR USE IN MEDICAL EQUIPMENT NOR ISO/TS16949 FOR USE IN AUTOMOTIVE 
APPLICATIONS OR OTHER SIMILAR MEDICAL AND AUTOMOTIVE STANDARDS. VICOR DISCLAIMS 
ANY AND ALL LIABILITY FOR INCLUSION AND/OR USE OF VICOR PRODUCTS IN SUCH EQUIPMENT OR 
APPLICATIONS AND THEREFORE SUCH INCLUSION AND/OR USE IS AT YOUR OWN RISK.

Terms of Sale

The purchase and sale of Vicor products is subject to the Vicor Corporation Terms and Conditions of Sale 
which are available at: 

(http://www.vicorpower.com/termsconditionswarranty)

Export Control

This document as well as the item(s) described herein may be subject to export control regulations. 

Export may require a prior authorization from U.S. export authorities.  

10/18

 

Rev 1.2 

Page 6

Contact Us: 

http://www.vicorpower.com/contact-us

Vicor Corporation

25 Frontage Road

Andover, MA, USA 01810

Tel: 800-735-6200

Fax: 978-475-6715

www.vicorpower.com

email

Customer Service: 

[email protected]

Technical Support: 

[email protected]

©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.

All other trademarks, product names, logos and brands are property of their respective owners.

Содержание VI Chip BCM

Страница 1: ... operating limits The data sheets are available for downloading at www vicorpower com It is important to remember the fast response of most BCMs can readily show the limitations of the source load and associated wiring connected to the evaluation board Care should be exercised to minimize stray source and load impedances in order to fully exercise the BCM Please refer to Figure 1 for locations of ...

Страница 2: ... 9 OUT OUT C1 BCM J1 TP1 TP2 TP7 TP4 TP6 TP5 OUT OUT C1 2 2 µF 450 V IN IN TM RSV PC J1 TP5 TP7 TP6 TP2 TP1 TP4 In PC RSV TM In Out Out Out Out BCM Figure 1 BCM evaluation board demo layout and dimensional drawing component side Figure 2 BCM evaluation board schematic ...

Страница 3: ... evaluation board can be connected directly to the application for which the BCM is intended However the interconnect impedances between the evaluation board and the application can greatly affect the transient response For applications where transient response is critical the user should consider mounting the BCM directly to the target application PCB Test points 6 OUT and 7 OUT can be used to mo...

Страница 4: ... bias supply a Connecting PC to the IN will disable the BCM b Connecting a DVM or oscilloscope between PC positive and IN negative will indicate the status of the BCM Please note that the BCM does not have active current sinking capability c Connecting a load between PC positive and IN negative will provide a primary referenced bias supply Efficiency Measurement As the BCM can deliver and consume ...

Страница 5: ...rator Be careful not to touch any exposed surface Certain BCMs may operate at potentially dangerous voltages use care in such cases The evaluation board is not intended for use in end item equipment Ordering Information The BCM evaluation boards can be ordered from the Vicor website www vicorpower com To order the demo boards substitute BCM with BCD in BCM part number See http www vicorpower com d...

Страница 6: ...ne whether the Vicor product is suitable and fit for your applications and products and to implement adequate design testing and operating safeguards for your planned application s and use s VICOR PRODUCTS ARE NOT DESIGNED AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT LIFE CRITICAL OR SAFETY CRITICAL SYSTEMS OR EQUIPMENT VICOR PRODUCTS ARE NOT CERTIFIED TO MEET ISO 13485 FOR USE IN MEDICAL EQUIP...

Страница 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Vicor BCD384F120T300A00 ...

Отзывы: