![VICOR PI352 series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/vicor/pi352-series/pi352-series_user-manual_1013370003.webp)
UG:307
vicorpower.com
Applications Engineering: 800 927.9474
Page 3
The evaluation board is designed to faciliatate the evaluation of the performance of Vicor’s mounted
ZVS buck product. Sockets are provided to permit quick probing. Input sockets can be used to place
a bulk capacitor. The evaluation board provides lugs, and bottom layer banana jack footprint for input
and output connections, signal connectors allowing wire, signal test points for easy connection to
standard test equipment, and Kelvin Johnson-Jack for accurate voltage measurements of power nodes.
Box Contents
The evaluation board ships with the following contents:
n
n
1 Customer evaluation board
n
n
3 x pre-installed jumpers
n
n
1 x hardware kit: 5 x size 10 screws, lugs and washers
Recommended Test Equipment
The following is a list of recommended test equipment.
1.
Safety glasses.
2.
DC power supply: Refer to the specific PI352x model datasheet to ensure the supply has sufficient
power and current capability.
3.
Electronic load: Refer to the specific PI352x model datasheet to ensure the load has sufficient
power handling and current capability for testing.
4.
Bench top cooling fan.
5.
Digital multi-meters (DMMs).
6.
Oscilloscope and probes.
7.
Interconnect wires, cables and fastening hardware.
Features
1.
Input and output lugs for source and load connections.
2.
Input sockets to place through-hole input aluminum-electrolytic capacitor.
3.
Input source filter (L102, R105).
4.
Toggle switch (S101) for enabling and disabling the regulator through the EN pin.
5.
Oscilloscope probe jack for accurate, high frequency input (J101) and output (J102) voltage
measurement.
6.
Signal pins test points and wire connectors.
7.
Kelvin voltage test points and sockets for all pins of the SiP product.
8.
Access to voltage switching node VS1 with a nearby ground receptacle.
9.
Mode selection switch for local (default) and remote sense loop.
10.
Trim control selection for both local and remote sense:
a.
ADJ: potentiometer to exercise the full output range.
b.
Fixed: resistor to set unit to nominal output.
11.
Local and remote sense AC signal injection (J201).