FlatPAC Family

50 to 600 Watt
AC-DC Switchers

Application Notes

Functional and Mechanical Layout

Installation and Operation Guidelines

Product Description

The FlatPAC family of user-definable offline power supplies provides a complete

power solution that incorporates one, two, or three standard Vicor DC-DC

converters and a front-end subassembly in a modular package. FlatPAC is available

with one, two, or three outputs and total output ratings of 50–600 W. These power

supplies feature an autoranging input, which automatically senses the input line

voltage and sets the power supply’s input range accordingly. FlatPAC’s unique

modular design accommodates over 10,000 different configurations. 

FlatPAC power supplies that contain BatMod current source modules instead of 

VI-200 converters are indicated by the suffix -BM following the FlatPAC part

number. BatMod converters provide a programmable output current, rather than a

regulated output voltage. Consequently, the output supervisory terminal functions

differ on FlatPACs with BatMod modules.

U-Series

Содержание FlatPAC Family AC

Страница 1: ...otal output ratings of 50 600 W These power supplies feature an autoranging input which automatically senses the input line voltage and sets the power supply s input range accordingly FlatPAC s unique modular design accommodates over 10 000 different configurations FlatPAC power supplies that contain BatMod current source modules instead of VI 200 converters are indicated by the suffix BM followin...

Страница 2: ...t 0 4 V 1 5m A Maximum external pullup is 70 Vdc AC OK and BUS OK signals are isolated and can have different reference levels V r AC OK 1 5mA max V r BUS OK 30mA max Disable MOD DIS V 1 5mA max FlatPAC AC Mains and Supervisory Connections External Supervisory Functions 2 up and 3 up models only MOD DIS MOD DIS AC OK AC OK BUS OK BUS OK Internal Supervisory Circuits Optocouplers AC Mains Earth Gro...

Страница 3: ...oad 90 180 Vac AC Line Timing Diagram Status Signals 2 up and 3 up models only Output Sense and Trim All models with VI 200s Load Battery Charger External Control Functions Programmable Current or Voltage Source 12 48V Battery Out VTRIM ITRIM I MON Out External Control Functions Out VTRIM ITRIM I MON Out Typical Applications Models with BatMods only Time Interval Min Typ Max Units Notes T1 T0 0 0 ...

Страница 4: ... Single output 300 600 W PU Series Dual output 100 400 W QU Series Dual output 150 600 W RU Series Triple output 150 600 W Inputs 1 MOD DIS 2 MOD DIS 3 AC OK 4 AC OK 5 BUS OK 6 BUS OK 7 AC in L1 8 AC in L2 N 9 Chassis Ground Outputs 10 Power Out 11 Out 12 Sense 13 Trim 14 Sense 15 Out 16 Power Out On FlatPACs containing BatMods 12 VTRIM 13 ITRIM 14 IMON For local sense connection only not for load...

Страница 5: ...NTING HOLE ø 0 15 0 01 THRU 6 PLACES OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 1 OUTPUT 1 OUTPUT 2 5 OUTPUT STUD CONNECTIONS SUPPLIED WITH FLATPAC 10 WASHER USER OUTPUT TERMINAL 10 WASHER 10 LOCK WASHER 10 NUT 10 NUT TORQUED TO 25 in lbs 2 8 N m AT THE FACTORY DO NOT LOOSEN Notes Connect paralleled outputs as shown MU NU and QU Series for 40 A out All output studs 10 32 UNF Torque to 20 in lbs 2 3 N m Inp...

Страница 6: ...100 A 4 AWG 20 A 30 A 10 AWG 6 A 10 A 16 AWG 50 A 75 A 6 AWG 15 A 20 A 12 AWG 0 A 6 A 18 AWG Output Voltage Trimming Do not trim the outputs higher than 110 of their nominal output voltage When an output is trimmed up do not exceed its maximum rated output power Operating Temperature Do not allow the FlatPAC to exceed its maximum operating temperature which is reached when the heat sink is 85 C Fu...

Страница 7: ...rmation The Vicor Applications Manual and product data sheet contain complete information about FlatPAC AC DC power supplies To receive literature or to consult an applications engineer about installation or operation of this product contact your nearest Vicor office or visit the Vicor Website See back panel Bitte lesen Sie die Sicherheits Vorschriften auf Seite 8 AMP and Faston are registered tra...

Страница 8: ... Spannung der Stromversorgung der Umgebungstemperatur und der Luftzirkulation über dem Kühlkörper ergibt Bitte bestimmen Sie mit Hilfe des Vicor Applikationshandbuches die maximale Umgebungstemperatur Ihrer Applikation Weitere Informationen Das Vicor Applications Manual und Produkt Datenblätter enthalten ausführliche Informationen über FlatPAC AC DC Wandler Fordern Sie bitte Unterlagen bei Vicor o...