Vicon VF-440R Скачать руководство пользователя страница 4

 

Important Safeguards 

GRAPHIC SYMBOL EXPLANATION

 

The lightening bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric 

shock. 

 

The exclamation point symbol alerts the user to the 

presence of important operating and maintenance 

instructions. 

 

1. Read Instructions -

  Read all safety and operating 

instructions before the product is operated. 

2. Retain Instructions -

  Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not  use caustic, abrasive or aerosol 

cleaners) 

 

a) 

For units that CAN BE DISCONNECTED from the 

power source, use a damp cloth for cleaning. 

b) 

For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

6. Attachments -

  Use only UL Listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

  Use only products designed for 

outdoor environments where they will be exposed to water or 

moisture. 

8. Accessories -

  Do not place the unit on an unstable 

surface to avoid falling. Use only UL Listed Vicon recommended 

mounting accessories. 

9. Ventilation -

  Do not block ventilating slots and openings 

as they ensure reliable operation. Do not place the unit near 

a heat source or into an enclosure unless recommended by 

Vicon. 

10. Power Sources -

  The product should only be operated 

from the recommended power source. Use only a UL Class 

2 indoor/dry or Class 3 outdoor/wet power supply. 

11. Grounding -

  Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power 

outlet. Contact an electrician to replace an obsolete outlet. 

Do not force a plug into a non-grounded outlet. 

12. Power Cord Protection -

  Power supply cords should 

not be routed in trafficked areas or in tight spaces where 

they will be pinched or used to bear weight. Allow some 

slack in the cord where it enters the unit. 

13. Outdoor Cable Grounding -

  Use only grounded 

outdoor cables to protect against voltage surges and static 

charges. Section 810 of the National Electrical Code, 

ANSI/NFPA 70-1984, provides information on proper 

grounding of the lead-in wire to an antenna discharge unit, 

size of grounding conductors and the requirements of 

grounding electrodes. 

14. Lightning  -

  Disconnect the product from its power 

source and cable system when possible to prevent damage 

due to lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power 

or utility lines where they can fall and make direct contact. 

Contact with power lines can be fatal. 

16. Overloading -

  Do not overload wall outlets and 

extension cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill 

liquid into, enclosure openings to prevent risk of fire or 

electric shock. 

18. Servicing -

  Refer all servicing to qualified service 

personnel. 

19. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b) 

Objects have fallen or liquid has been spilled into the 
product. 

c) 

The product is not designed for outdoor use and has 
been exposed to water or moisture. 

d) 

The product does not operate per the operating 
instructions. Perform Vicon recommended 
adjustments, modifications and troubleshooting only to 
avoid unit damage and personal injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in 
performance. 

 

20. Replacement Parts -

  Use only Vicon specified 

replacement parts or an approved equivalent to prevent unit 

damage and injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

  Take all normal electrostatic 

discharge precautions to avoid component damage during 

installation and operation. 

23. For 230 VAC Devices Only -

  When the disconnect 

device is not incorporated in the equipment or when the plug 

on the power supply is intended to serve as the disconnect 

device, follow the guidelines below: 

 

a) 

For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into 

the site wiring. 

b) 

For 230 VAC units with a plug, the outlet must be 

installed near the unit and be easily accessible. 

 

 

 

 

Содержание VF-440R

Страница 1: ...All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK...

Страница 2: ......

Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Страница 4: ...Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead...

Страница 5: ...video inputs Each video input modulates a separate FM carrier frequency to allow the total of four video signals to be combined onto one fiber The VF 440 Series is designed to operate over an optical...

Страница 6: ......

Страница 7: ...the VF SR 20 2 and VF PSR 2 instruction manual XX164 60 for further details Power Connection On standalone units power is supplied to the unit via a three pin Phoenix connector The ground wire from th...

Страница 8: ...VF 440 Receiver VF 440 Transmitter...

Страница 9: ...dicators to aid in installation and troubleshooting VLI 1 through VLI 4 VF 440T A green LED indicator is provided for each of the four video channel inputs Video status associated with each of these L...

Страница 10: ...installation and troubleshooting VLI 1 through VLI 4 VF 440TR A bi color LED indicator is provided for each of the four video channel inputs Video status associated with each of these LEDs is summariz...

Страница 11: ...ries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company r...

Страница 12: ...utput Signal Differential Phase Differential Gain Signal to Noise Ratio Interconnection Distance recommended Optical Wavelength Maximum Optical Attenuation Loss Budget 50 or 62 5 3 1 mi 5 km on 62 5 c...

Страница 13: ...authorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if...

Страница 14: ...s Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 47...

Отзывы: