background image

ii  

  Important Safeguards 

 

XX164-50-01 VF-1400 Transmission System 

Important Safeguards 

GRAPHIC SYMBOL EXPLANATION

 

The lightening bolt symbol alerts the user to the presence of 
dangerous voltage that may present the risk of electric 
shock. 

 

The exclamation point symbol alerts the user to the presence 
of important operating and maintenance instructions. 

 

1. Read Instructions -

 Read all safety and operating 

instructions before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol 

cleaners) 

 

a)  For units that CAN BE DISCONNECTED from the 

power source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the 

power source, use a damp cloth for cleaning and do not 
allow moisture or liquids to enter vents. 

6. Attachments -

 Use only UL Listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for 

outdoor environments where they will be exposed to water or 
moisture. 

8. Accessories -

 Do not place the unit on an unstable 

surface to avoid falling. Use only UL Listed Vicon recommended 
mounting accessories. 

9. Ventilation -

 Do not block ventilating slots and openings 

as they ensure reliable operation. Do not place the unit near 
a heat source or into an enclosure unless recommended by 
Vicon. 

10. Power Sources -

 The product should only be operated 

from the recommended power source. Use only a UL Class 
2 indoor/dry or Class 3 outdoor/wet power supply. 

11. Grounding -

 Only products equipped with a 3-prong 

grounded plug should be inserted into a grounded power 
outlet. Contact an electrician to replace an obsolete outlet. 
Do not force a plug into a non-grounded outlet. 

12. Power Cord Protection -

 Power supply cords should not 

be routed in trafficked areas or in tight spaces where they 
will be pinched or used to bear weight. Allow some slack in 
the cord where it enters the unit. 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 

Section 810 of the National Electrical Code, ANSI/NFPA 70-
1984, provides information on proper grounding of the lead-
in wire to an antenna discharge unit, size of grounding 
conductors and the requirements of grounding electrodes. 

14. Lightning -

 Disconnect the product from its power 

source and cable system when possible to prevent damage 
due to lightning and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power 

or utility lines where they can fall and make direct contact. 
Contact with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and 

extension cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill 

liquid into, enclosure openings to prevent risk of fire or 
electric shock. 

18. Servicing -

 Refer all servicing to qualified service 

personnel. 

19. Damage Requiring Service -

 Obtain service when: 

 
a)  The power-supply cord or plug is damaged. 
b)  Objects have fallen or liquid has been spilled into the 

product. 

c)  The product is not designed for outdoor use and has 

been exposed to water or moisture. 

d)  The product does not operate per the operating 

instructions. Perform Vicon recommended adjustments, 
modifications and troubleshooting only to avoid unit 
damage and personal injury. 

e)  The product has been dropped. 
f)  The product shows a significant change in 

performance. 

 

20. Replacement Parts -

 Use only Vicon specified 

replacement parts or an approved equivalent to prevent unit 
damage and injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic 

discharge precautions to avoid component damage during 
installation and operation. 

23. For 230 VAC Devices Only -

 When the disconnect 

device is not incorporated in the equipment or when the plug 
on the power supply is intended to serve as the disconnect 
device, follow the guidelines below: 
 
a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into 
the site wiring. 

b)  For 230 VAC units with a plug, the outlet must be 

installed near the unit and be easily accessible. 

 

 

Содержание VF-1400 Series

Страница 1: ...tries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 WEB www vicon cctv com ...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...etermined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If nece...

Страница 6: ... unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides information on proper grounding of the lead in wire to an antenna discharge unit size of grounding conductors and the requirements of grounding electrodes 14 Lightning Disconnect the product from its power sour...

Страница 7: ... model VF 1400RR The transmitter operates with the receiver over one multimode fiber optic cable The system converts a single video input and a single RS 422 input into an optical output using a 1300 nm wavelength source It also converts an optical control signal returning on the same fiber into a RS 422 output signal using an 850 nm wavelength detector The VF 1400 Series is designed to operate ov...

Страница 8: ......

Страница 9: ...ections The fiber optic connection is made via a ST connector located on the side of the standalone units and the back of the rack mount units Video input output connections are located on the side of the standalone units and the back of the rack mount units A BNC connector is provided for each channel The video inputs are connected to an appropriate 75Ω baseband video source such as a camera or a...

Страница 10: ...4 Power Connection XX164 50 01 VF 1400 Transmission System VF 1400R VF 1400T VF 1400RR Figure 1 Typical Installation Diagrams ...

Страница 11: ...ower and optical input status associated with this LED is summarized below Optical Level Indicator DC Power Status Optical Status Green On Proper Optical Input Power Present Red On Optical Input not Detected Off Off Check Power Supply Data TX A green LED indicator is provided to monitor the RS 422 input data from the electrical interface through the VF 1400 and out onto the fiber The intensity of ...

Страница 12: ...6 Status Indicators XX164 50 01 VF 1400 Transmission System Figure 2 Indicators ...

Страница 13: ...es in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circum...

Страница 14: ...eight 1 9 in 48 mm Width 5 875 in 149 mm Depth 3 75 in 95 mm Rack Mount 1 rack slot Standalone 0 67 lb 0 3 kg Rack Mount 0 46 lb 0 2 kg Aluminum Standalone Silver Rack Mount Black paint No 8 3 mm hardware 4 places Standalone Height 3 1 in 79 mm Width 6 0 in 152 mm Depth 10 5 in 267 mm Rack Mount Height 1 2 in 31 mm Width 6 in 152 mm Depth 8 8 in 223 mm Standalone 1 7 lb 0 8 kg Rack Mount 0 6 lb 0 ...

Страница 15: ...fective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s sole discretion Vicon rese...

Страница 16: ...rters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: