background image

www.vicon-security.com

                                              

XX224-30-07

V960D Series Network  

Indoor Camera Domes

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the 

operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed 

to be used in life-critical situations and must not be used for this purpose.

Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788

Tel: 631-952-2288  Fax: 631-951-2288 Toll Free: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 

Document Number: 8009-8224-30-07 
Product specifications subject to change without notice.  

Issued: 1112

Copyright © 2012 Vicon Industries Inc. All rights reserved.

Installation Guide

Содержание V960D Series

Страница 1: ...entation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge New York 11788 Tel 631 952 2288 Fa...

Страница 2: ...ream H 264 13 4 Setup 14 5 Installation 15 5 1 Installation Mode 15 6 Video 15 6 1 Video Codec 16 6 2 Camera 19 6 2 1 Exposure Control 19 6 2 2 Day Night Control 20 6 2 3 White Balance Control 20 6 2...

Страница 3: ...pping 31 12 Network 32 12 1 IP Setup 32 12 2 Service Port 34 12 3 RTP 35 12 4 E mail 35 12 5 DDNS 36 12 6 UPnP 37 13 1 User 39 12 2 Date Time 40 13 3 Maintenance 41 13 4 Information 43 Vicon Standard...

Страница 4: ......

Страница 5: ...mera with a 3 3 12 mm varifocal lens V961D N312M 720P 1280x1024 1 3 megapixel resolution camera with a 3 3 12 mm motorized varifocal lens V961D N922M 720P 1280x1024 1 3 megapixel resolution camera wit...

Страница 6: ...en using a PoE switch router or injector 2 Power Connector 12 VDC or 24 VAC screw terminal power connector 3 I O Terminal Block for Audio and Alarm 3 1 Audio In Audio in line level for line in mono si...

Страница 7: ...ration to its factory default settings 6 Status LED LED Color Indication System Status Status Green right On Network connection is established Flash Camera is booting up Red left Flash Firmware Upload...

Страница 8: ...amera and that the location can support the weight of the unit the V960D unit weighs 0 9 lb 400 g Cables must be routed to the installation location The V960D mounts directly to a ceiling or wall Prep...

Страница 9: ...unter clockwise Then secure the unit with the two supplied tapping screws 3x8 3 Attach the top cover to the unit 2 1 Adjusting the Camera Direction The camera body is set in a 3 axis gimbal mount allo...

Страница 10: ...the address bar If you do not know the IP address of your camera use the Multi Upgrade Tool on the Installation CD and use the Search function The IP address of your camera will display in the list R...

Страница 11: ...ive X control from the camera to display a Live image NOTE The layout of the live view page in the camera may have been customized to meet specific requirements Consequently some of the examples and f...

Страница 12: ...r 3 Check the image from the Live view page on your web browser Set Installation Mode to OFF to resume normal camera operation NOTE DC Auto Iris should always be disabled while focusing the camera Thi...

Страница 13: ...time transmission of multimedia data via Unicast or Multicast RTSP Real Time Streaming Protocol serves as a control protocol to negotiate the type of transport protocol used for the stream RTSP is us...

Страница 14: ...ge of bandwidth especially when there are large numbers of clients viewing simultaneously Note however that a multicast broadcast could not pass a network router unless the router is configured to all...

Страница 15: ...strators who have unrestricted access to all settings under the Setup tab Users who have access to the Video Image Live View and Event Configuration sections Accessing the Setup link from a browser 1...

Страница 16: ...itor in order to adjust the positioning of the camera and focus the lens ON Analog Output is enabled both IP video streams are set to VGA 640 x 480 resolution OFF Analog Output is disabled NOTE You mu...

Страница 17: ...clients accessing Motion JPEG streams could use different image settings H 264 This is a video compression standard that makes good use of bandwidth and could provide high quality video streams at les...

Страница 18: ...for VGA 640x480 800Kbps 1Mbps Recommended bit rate for 720p 1280x720 3Mbps 4Mbps Recommended bit rate for 1080p 1920x1080 6Mbps 8Mbps Boost Quality The Boost feature is used in conjunction with Video...

Страница 19: ...20 x 240 CIF 352 x 240 288 CIF 352 x 240 288 QVGA 320 x 240 QVGA 320 x 240 Only available in MJPEG mode Frame rate will be limited to 15 fps on both streams Output resolution table for 720p HD model F...

Страница 20: ...se this setting for automatic exposure control MANUAL Use this setting to control camera exposure manually To compensate for poor lighting conditions you can adjust the Color level Brightness Sharpnes...

Страница 21: ...mera behaves at low light levels These settings affect video image quality and how much noise is in the images Select ON or OFF 6 2 2 Day Night Control Day Night Mode AUTO DAY NIGHT Set this filter to...

Страница 22: ...0 30 Default 15 Hue 0 30 Default 15 6 2 5 Motorized Lens Adjustment for models with motorized lens only Adjust the lens Zoom Focus and Iris if applicable from this window One Push Focus Camera will au...

Страница 23: ...the camera Enable Audio Audio can be turned on or off by selecting ENABLE or DISABLE from the dropdown list Codec Select G 711 u law MIC Speaker Volume Select a volume for the microphone and speakers...

Страница 24: ...wer Setup Live View Protocol RTP Unicast UDP RTP Multicast UDP RTP over RTSP TCP Buffering Time frame based Determines 0 90 x 1 30 sec 0 3 sec Viewer OSD Setup Date Determines whether the date is disp...

Страница 25: ...e SD Status Shows present SD card status It also shows whether the SD card is present and the capacity left on it in kilobytes KB SD Safety Remove Mount Unmount buttons The Mount button notifies the s...

Страница 26: ...e in the Video Codec section and second stream to M JPEG or None SD Writing SD Writing will Enable Disable event recording to the SD card When Disabled all remaining menus will be deactivated Director...

Страница 27: ...ical Periodical SD Writing This is the setting page to save the still shot in the Micro SD card periodically NOTE This function cannot be used when Installation mode is turned ON Set the first stream...

Страница 28: ...he SD Card Client Configuration Allows transmission of still images to remote sites using the FTP server Set the information for FTP transmission by inserting the IP address Username and Password of t...

Страница 29: ...o the SD card on an event it transmits to the FTP server configured in the FTP Config menu 10 3 Periodical Periodical FTP Sending Allows transmission of still images periodically to the FTP server of...

Страница 30: ...in the Text field Alarm Output relay output This could drive a maximum load of 60 VDC or 120 VAC at 2 A directly If the output is used with an external relay a diode must be connected in parallel wit...

Страница 31: ...located and adjust the size of the area by dragging the outlined box across and down in one motion 4 Adjust the Object Sensitivity from the drop down list 1 10 The Sensitivity list only displays when...

Страница 32: ...with certain actions A triggered event happens as a result of an event which is mapped within this menu This could be caused by motion detection or an external alarm input Alarm Out events could be t...

Страница 33: ...ng a Dynamic Domain Name Service DDNS NOTE IP address assignment via DHCP may lead to the situation where the IP address changes and you lose contact with the camera If your DHCP server can update a D...

Страница 34: ...tomatically 1 After the list of detected devices appears select the camera you are trying to configure 2 Select the Network type as Static or DHCP If Static is selected enter all of the network inform...

Страница 35: ...TTPS Port HTTPS will be supported in future versions The default HTTPS port number 443 could be changed to any port within the valid range 1024 65535 HTTPS is used to provide encrypted web browsing NO...

Страница 36: ...Port Range The IP address port numbers and Time To Live TTL value are for use for the video stream s in Multicast H 264 format Only certain IP addresses and port numbers should be used for Multicast...

Страница 37: ...DNS can provide your camera with its own name server address URL which can then be used to access it over the Internet The product can be unregistered from the service at any time To do this click Net...

Страница 38: ...12 6 UPnP Universal Plug Play UPnP allows you to find the IP camera automatically on your network...

Страница 39: ...y you must enable the UPnP function on both the camera and on your PC Camera Set UPnP to ON PC Open Control Panel Network Connection Select Advanced Optional Networking Components Select Network Servi...

Страница 40: ...user name ADMIN and password 1234 to log in To change the password or add a user go to Setup System User Fill in the User ID Password and E mail server Select the Group Then press the Add button and...

Страница 41: ...P server every 60 minutes Specify the IP address or host name of the NTP server you are using This can also be done manually Local Time PC Sync SAVE Specify local time manually or synchronize the time...

Страница 42: ...e firmware will be released to update the camera which will contain feature additions and other improvements Always read the upgrade instructions and release notes that accompany each new firmware rel...

Страница 43: ...ng the web browser 1 Go to SETUP System Maintenance 2 Click Factory Default Button and wait 1 minute for camera to reboot Using the Reset Button on the camera 1 After the camera is powered up i e LED...

Страница 44: ...13 4 Information System Information After updating firmware you can confirm the new F W version here...

Страница 45: ......

Страница 46: ......

Страница 47: ...policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been...

Страница 48: ...quarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5...

Отзывы: