MODEL V707
8
ELECTRICAL
Power Requirements:
Surface Mount:
24 VAC 50/60 Hz,
13.5 - 16 VDC.
Rack Mount (all):
13.5 - 16 VDC.
Current Requirement:
Surface Mount:
350 mA.
Rack Mount (all):
600 mA
Power Consumption:
Surface Mount:
5.0 W.
Rack Mount:
9.0 W.
Heat Equivalent:
Surface Mount:
0.28 btu/min (0.07 kg-cal/min).
Rack Mount:
0.5 btu/min (0.13 kg-cal/min).
Note: These figures represent the conversion of 100% of the elec-
trical energy to heat. Actual percentage of heat generated will be
less and will vary from product to product. These figures are pro-
vided as an aid in determining the extent of cooling required for an
installation.
Safety Standard:
UL 1950.
Radio Frequency
Emissions Rating:
FCC Class A.
European Community
(CE) Standards:
EN60950.
VIDEO
Number of Channels:
4.
Formats Supported:
NTSC, PAL and SECAM.
Full System Bandwidth:
6 MHz per channel.
Horizontal Video Resolution:
480 TV lines.
Input/Output Impedance:
75 ohms.
Optimum Input Signal:
1 V p-p nominal composite video.
Output Signal Level:
1 V p-p nominal, composite video,
unity gain, ±5%.
Differential Phase:
0.7º.
Differential Gain:
2%.
Signal-to-Noise Ratio:
>55 dB (0 dB loss).
Interconnection Distance:
Video devices to transmitter:
≤
100 ft (30 m).
Receiver to video devices:
≤
100 ft (30 m).
Note: RG59/U coaxial cable, Belden No. 9259 or equivalent, is
recommended for video interconnection.
OPTICAL
Maximum
Optical Attenuation:
13 dB.
Gain Control:
Fully automatic optical (OAGC).
Optical Wavelength:
1300 nm.
Operating Distance:
3.2 mi (5.2 km).
Note: Operating distance is approximate and will be affected by
the type and number of splices in the fiber and by the exact type
of fiber used.
Fiber Type:
62.5 um.
Modulation Type:
Digital Time Division Multiplexing
(TDM).
TECHNICAL INFORMATION