Vicon V20A Скачать руководство пользователя страница 13

X523 Rev 998 V20A Pole Mounting Adapter 

Maintenance  

••

  7 

Extending the Chain Length 

If a large diameter pole (up to 10 inches) is being used, the 18-inch chain and the 24-inch chain must be linked 
together with a connecting chain link provided. 
 

1.  Separate both halves of the connecting chain link. 

2.  Insert one of the connecting chain link halves through one end of both an 18-inch chain and a 24-inch chain. 

3.  Insert the other connecting chain link component through the same links as in step 2. 

4.  Place the connecting chain link halves over one another, making sure the pins are inserted in the holes. 

Strike all four pins with a small hammer to set the pins, making sure the link can not come apart. 

 

 

 

Figure 3 

Connecting Chain Link Installation 

Maintenance 

Model V20A does not require any maintenance. 

Содержание V20A

Страница 1: ...to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Vicon Part No 8006 8532 01 00 Section 7 Rev 998 VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11...

Страница 2: ......

Страница 3: ...deo systems and equipment for use in a wide variety of security safety control surveillance and communication applications We stand behind the quality and dependability of every product with an indust...

Страница 4: ......

Страница 5: ...lation 3 Unpacking and Inspection 3 Inspection For Visible Damage 3 Inspection For Concealed Damage 3 Installation Preparation 3 Bracket to Plate Installation 4 Plate to Pole Installation 5 Extending...

Страница 6: ...Rev 998 V20A Pole Mounting Adapter List of Figures Figure 1 Installing the Pole Mount Brackets to the Pole Adapter Plate 5 Figure 2 Pole Mounting Adapter Assembly Installation 6 Figure 3 Connecting Ch...

Страница 7: ...con s medium and heavy duty wall mounts for outdoor installation Compatible mounts are V24WM V2400WM V2400AWM V1600WM V2000WM V7UWM and V5UWM Designed to be installed on a pole with a minimum diameter...

Страница 8: ......

Страница 9: ...nd inspect it for concealed damage Do not discard the carton or packing materials If the unit is damaged contact the carrier immediately and request forms for filing a damage claim Make arrangements f...

Страница 10: ...tem 2 to 1 9 5 16 18 nut 8 6 used Secures item 8 10 5 16 lock washer 8 6 used Secures item 8 11 Flat washer 8 6 used Secures item 8 12 Strain relief plugs 3 Plugs unused cable entries 13 Liquid tight...

Страница 11: ...tension nut 5 Place the pole adapter plate against the pole 6 Insert each chain end into the opening on each side of the upper pole mount bracket adjusting the length equally for minimum slack while...

Страница 12: ...6 Installation X523 Rev 998 V20A Pole Mounting Adapter Figure 2 Pole Mounting Adapter Assembly Installation...

Страница 13: ...sert one of the connecting chain link halves through one end of both an 18 inch chain and a 24 inch chain 3 Insert the other connecting chain link component through the same links as in step 2 4 Place...

Страница 14: ...in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a...

Страница 15: ...ation 9 Technical Information MECHANICAL Load Rating Depends on wall mount used Pole Diameter 3 10 inches 7 6 25 cm Dimensions Height 12 4 in 31 5 cm Width 9 5 in 24 1 cm Depth 3 9 in 9 9 cm Weight 15...

Отзывы: