background image

 

8  

••

 Maintenance 

X458 Rev 700 V1101C 

Maintenance 

Repairs should only be attempted by skilled personnel in an adequately equipped facility. 
 
 
 

Shipping Instructions 

Use the following procedure when returning a unit to the factory: 
 

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of 

the Vicon employee who issued the R.A. 

 

Vicon Industries Inc. 
89 Arkay Drive 
Hauppauge, NY  11788 
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) 

 

For service or returns from countries in Europe, contact: 

 

Vicon Industries (U.K.) Ltd 
Brunel Way 
Fareham, PO15 5TX 
United Kingdom 
Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322 

 

2. 

Attach a sheet of paper to the unit with the following information: 

 

a. 

Name and address of the company returning the unit 

b. 

Name of the Vicon employee who issued the R.A. 

c. 

R. A. number 

d. 

Brief description of the installation 

e. 

Complete description of the problem and circumstances under which it occurs 

f. 

Unit’s original date of purchase, if still under warranty 

 

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 

4.  Mark the R.A. number on the outside of the carton on the shipping label. 
 

Содержание V1101C

Страница 1: ...ice Vicon and its logo are registered trademarks of Vicon Industries Inc WARNING TO PREVENT RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 INFOFAX 800 287 1207 WEB www vi...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...spection For Concealed Damage 3 Wiring the Unit 3 Wiring the Pan and Tilt 3 Wiring the Motorized Lens 4 Wiring the Housing 4 Testing and Adjustment Procedures 5 For All Adjustments 5 Output Voltage Selection 5 Housing Controls 6 Operation 7 Power 7 Pan and Tilt 7 Lens 7 Maintenance 8 Shipping Instructions 8 Technical Information 9 ...

Страница 6: ......

Страница 7: ...an and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Accessories Do not place this video product on any unstable surface or table The video product may fall causing serious injury to a person and serious damage to the video product Use only with a mounting accessoryrecommended by Vicon or sold with the video product Any mounting of the video product should ...

Страница 8: ...t in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 19 Damage Requiring Service Disconnect this video product from its power source and refer servicing to qualified serv...

Страница 9: ...e attempting installation The V1101C is a multifunction unit that controls pan and tilt drives lens functions and housing accessories The unit features the P TPAD multiposition front panel disc for manual control of pan and tilt functions and an autopan control switch for automatic operation Operating controls including zoom f ocus iris and speed comprise the manual lens drive functions The V1101C...

Страница 10: ...2 Introduction X458 Rev 700 V1101C Notes ...

Страница 11: ...rms for filing a damage claim Make arrangements for a representative of the carrier to inspect the damaged equipment If the equipment must be returned for repair follow the Shipping Instructions at the end of this manual Wiring the Unit Each V1101C Control is supplied with a complete set of mating connectors for housing pan and tilt and lens control Fabricate interconnecting cables according to th...

Страница 12: ...d Copper Maximum Distance for Voltge ft m Low Medium High 22 900 270 2100 640 3300 1000 20 1400 430 3300 1000 5300 1600 18 2300 700 5400 1650 8400 2600 Figure 3 Lens Interconnection Diagram Wiring the Housing Prepare the interconnecting cable assembly for the housing according to Figure 4 Select the wire size from Table 2 Table 2 Housing Operating Distances Cable Size AWG Maximum Distance to Contr...

Страница 13: ...iously selected and press the ZOOM IN push button to enlarge the image of the distant object in the field of view Pressing ZOOM OUT causes a much larger portion of the scene to be included in the monitor image producing a wide angle effect 5 Operate the IRIS OPEN push button The scene viewed on the monitor becomes lighter Then press the IRIS CLOSE push button The scene becomes darker Output Voltag...

Страница 14: ...ure 5 Lower Housing Retaining Screw Location Housing Controls The CAM camera switch controls the power to the camera Press once for power on press again for power off The WIPR wiper switch turns the window wiper accessory on or off The WSHR washer accessory is designed to direct a small high pressure stream of water at the window To obtain the best washing action turn the wiper on first Operate th...

Страница 15: ...to have priority over the autopan function it is not necessary to place the control in the manual mode if the operator wishes to momentarily interrupt autopan operation Lens Operating controls and their corresponding functions are listed in Table 3 All controls except for the output voltage switch are located on the front panel To access the output voltage switch follow the instructions under Outp...

Страница 16: ...r service or returns from countries in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete ...

Страница 17: ...or an installation Output Voltage Pan and Tilt 24 VAC Lens 2 8 VDC Housing 24 VAC Line Cord Standard three conductor SV No 18 AWG cable with grounding plug Fuse 120 VAC 3 A 3 AG 230 VAC 1 5 A 3 AG Cable Requirements Pan and Tilt 8 conductor unshielded Lens 5 conductor shielded Housing 6 conductor unshielded Connectors P T output Vicon part no 1806 5003 07 Mating connector supplied Lens output Vico...

Страница 18: ...ton OPEN CLOSE Speed knob control Iris response three position switch low medium high internal Output voltage three position switch slow medium fast internal Pan and Tilt Functions Pan and tilt multiposition disc Autopan push button on off latching switch Power Indicator LED MECHANICAL Overall Dimensions max Height 3 13 in 79 5 mm Width 10 0 in 254 mm Depth 8 in 203 mm Weight 4 5 lb 2 0 kg Constru...