9. Loosen the 3 captive screws on the bottom plate and open it.
9. 10. Feed the unterminated CAT5 cable through the hole in the solid
grommet and terminate the cable with the appropriate connector. If
using terminated CAT5 cable, use RJ-45 cap provided to help push the
connector through the grommet with hole.
Wiring Diagram for Alarm Inputs/Outputs
DI (Alarm In)
Trigger (Low)
0-0 ~ 4 V
Trigger (High)
3.3 ~12 V
DO (Alarm Out)
V in (max)
30 V
I out (max)
100 mA
Note:
To maintain watertight
intergity/warranty, be sure to use the
appropriate grommet
.
t
.
Note: If using the I/O cables, use the I/O
cable assembly provided and plug them
into the appropriate connector on the PCB.
Cables will be run through the grommet on
the cover and terminated to the accessory