XX163-11-00 Rev 1006 SVFT-PRS Pressurized Dome Housing 

Important Safeguards  

  i 

Important 
Safeguards 

GRAPHIC SYMBOL EXPLANATION 

The lightening bolt symbol alerts the user to the presence of 

dangerous voltage that may present the risk of electric shock. 

 

The exclamation point symbol alerts the user to the presence of 

important operating and maintenance instructions. 

 

1. Read Instructions -

 Read all safety and operating instructions 

before the product is operated. 

2. Retain Instructions -

 Retain all safety and operating 

instructions for future reference. 

3. Heed Warnings -

 Pay attention to all product warnings. 

4. Follow Instructions -

 Follow all operating instructions. 

5. Cleaning -(Do not use caustic, abrasive or aerosol cleaners) 

a)  For units that CAN BE DISCONNECTED from the power 

source, use a damp cloth for cleaning. 

b) For

 

units that CANNOT BE DISCONNECTED from the power 

source, use a damp cloth for cleaning and do not allow 
moisture or liquids to enter vents. 

6. Attachments -

 Use only UL listed Vicon recommended 

attachments to prevent unit damage and personal injury. 

7. Water and Moisture -

 Use only products designed for outdoor 

environments where they will be exposed to water or moisture. 

8. Accessories -

 Do not place the unit on an unstable surface to 

avoid falling. Use only UL listed Vicon recommended mounting 

accessories. 

9. Ventilation -

 Do not block ventilating slots and openings as they 

ensure reliable operation. Do not place the unit near a heat source 

or into an enclosure unless recommended by Vicon. 

10. Power Sources -

 The product should only be operated from 

the recommended power source, UL listed Class 2 indoor/dry or 

Class 3 outdoor/wet power supply. 

11. Grounding -

 Only products equipped with a 3-prong grounded 

plug should be inserted into a grounded power outlet. Contact an 

electrician to replace an obsolete outlet. Do not force a plug into a 

non-grounded outlet. 

12. Power Cord Protection -

 Power supply cords should not be 

routed in trafficked areas or in tight spaces where they will be 

pinched or used to bear weight. Allow some slack in the cord 

where it enters the unit. 

13. Outdoor Cable Grounding -

 Use only grounded outdoor 

cables to protect against voltage surges and static charges. 

Section 810 of the National Electrical Code, ANSI/NFPA 70-1984, 

provides information on proper grounding of the lead-in wire to an 

antenna discharge unit, size of grounding conductors and the 

requirements of grounding electrodes. 

14. Lightning -

 Disconnect the product from its power source and 

cable system when possible to prevent damage due to lightning 

and power-line surges. 

15. Power Lines -

 Do not locate outside cables over power or 

utility lines where they can fall and make direct contact. Contact 

with power lines can be fatal. 

16. Overloading -

 Do not overload wall outlets and extension 

cords to prevent risk of fire and electric shock. 

17. Object and Liquid Entry -

 Never probe through, or spill liquid 

into, enclosure openings to prevent risk of fire or electric shock. 

18. Servicing -

 Refer all servicing to qualified service personnel. 

19. Damage Requiring Service -

 Obtain service when: 

 

a) 

The power-supply cord or plug is damaged. 

b) 

Objects have fallen or liquid has been spilled into the product. 

c) 

The product is not designed for outdoor use and has been 
exposed to water or moisture. 

d) 

The product does not operate per the operating instructions. 
Perform Vicon recommended adjustments, modifications and 
troubleshooting only to avoid unit damage and personal injury. 

e) 

The product has been dropped. 

f) 

The product shows a significant change in performance. 

 

20. Replacement Parts -

 Use only Vicon specified replacement 

parts or an approved equivalent to prevent unit damage and injury. 

21. Safety Check -

 Request safety checks to be performed 

following repair or maintenance to verify proper operation. 

22. ESD Precaution -

 Take all normal electrostatic discharge 

precautions to avoid component damage during installation and 

operation. 

23. For 230 VAC Devices Only -

 When the disconnect device is 

not incorporated in the equipment or when the plug on the power 

supply is intended to serve as the disconnect device, follow the 

guidelines below: 

 

a)  For permanently connected 230 VAC units, a readily 

accessible disconnect device must be incorporated into the 

site wiring. 

b)  For 230 VAC units with a plug, the outlet must be installed 

near the unit and be easily accessible. 

 

 
 

Содержание SVFT-PRS22E

Страница 1: ...his system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2006 Vicon Industries Inc All rights reserved Product specifications subject to...

Страница 2: ......

Страница 3: ...the unit 13 Outdoor Cable Grounding Use only grounded outdoor cables to protect against voltage surges and static charges Section 810 of the National Electrical Code ANSI NFPA 70 1984 provides informa...

Страница 4: ...an be determined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipme...

Страница 5: ...nd Assembling the 23 Pin Connector 6 Preparing the Camera Drive 8 Setting the DIP Switches 8 Pressurizing the Housing Assembly 9 Pipe Mount Method 11 Installing the Pipe Mount 11 Installing the 23 Pin...

Страница 6: ...iv Quick Installation XX163 11 00 Rev 1006 SVFT PRS Pressurized Dome Housing Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N...

Страница 7: ...s SVFT PRS Pressurized Dome Housing Components The SVFT PRS consists of a pressurized enclosure a sealed lower dome assembly and mounting brackets for the SurveyorVFT Camera Drive In addition the hous...

Страница 8: ...oor with clear lower dome coaxial output NTSC PAL SVFT PRS35 SVFT PRS35C 9103 00 9103 01 PRESSURIZED COLOR CAMERA DOME SYSTEM includes variable speed drive 35X high resolution day night camera lens ou...

Страница 9: ...and clip are provided on the inside to connect the camera drive latch during installation The lower side of the housing is equipped with a fill valve Schraeder type the top has a pressure switch and...

Страница 10: ...pilot holes for lag screws Note Verify there are no obstacles behind the surface before drilling 3 Place a bead of silicone sealant around the wall mount mounting flange press it to the surface and li...

Страница 11: ...ere could be optional site cables for alarm inputs or the relay output jacketed twisted pair b Verify that each cable has had the jacket stripped back If not strip back the jacket and individual wire...

Страница 12: ...cables through the provided connector strain relief fitting and push the connector near the shrink wrap tubing d Prepare each cable by stripping back the jacket and individual wire covering to the di...

Страница 13: ...n the gasket area If there is wipe this surface clean with a cloth 11 Lift the top of the housing assembly up to the wall mount s pressurized housing mounting flange Align the two 2 sets of four 4 mou...

Страница 14: ...witches 5 8 Pelco Switch 5 is ON switches 6 8 are OFF Sensormatic Switch 6 is ON switches 5 7 8 are OFF Ultrak Switches 5 and 6 are ON switches 7 8 are OFF Philips Switch 7 is ON switches 5 6 8 are OF...

Страница 15: ...fitting as shown in Figure 5 regulate the gas pressure to 10 0 psi 0 68 atm or bars 25 Attach the fill fitting to the housing assembly s fill valve located at the lower side of the housing and pressu...

Страница 16: ...10 Installation XX163 11 00 Rev 1006 SVFT PRS Pressurized Dome Housing...

Страница 17: ...icient strength to support the mount and unit and as vertically level as possible 2 Install a vertically hung 1 1 2 in 38 mm diameter NPT schedule 40 pipe with a coupling on the end 3 Using the provid...

Страница 18: ...85 and video RG 59 or twisted pair cable There could be optional site cables for alarm inputs or the relay output jacketed twisted pair b Verify that each cable has had the jacket stripped back If not...

Страница 19: ...et down the cable bundle c Route all cables through the provided connector strain relief fitting and push the connector near the shrink wrap tubing d Verify that each cable has had the jacket stripped...

Страница 20: ...is on the gasket area If there is wipe this surface clean with a cloth 11 Lift the top of the housing assembly up to the wall mount s pressurized housing mounting flange Align the two 2 sets of four 4...

Страница 21: ...Switches 5 8 Pelco Switch 5 is ON switches 6 8 are OFF Sensormatic Switch 6 is ON switches 5 7 8 are OFF Ultrak Switches 5 and 6 are ON switches 7 8 are OFF Philips Switch 7 is ON switches 5 6 8 are O...

Страница 22: ...egulated source of dry Nitrogen gas with the proper Schraeder type fill fitting as shown in Figure 9 regulate the gas pressure to 10 0 psi 0 68 atm or bars 25 Attach the fill fitting to the housing as...

Страница 23: ...Rev 1006 SVFT PRS Pressurized Dome Housing Installation 17 Warning Do not use any gas type other than dry Nitrogen The use of Shop Air can introduce moisture into the housing assembly that can damage...

Страница 24: ...sing speed disk write speed and display card strength Storage size and location types including local Workstation recording attached SCSI RAID and integrated NAS SAN devices The default parameters on...

Страница 25: ...C VUG Select TAB The SELECT TAB allows the user to select the relevant IP Unit in order to change its settings or to upgrade its version 1 From the Unit selection list select the relevant IP product...

Страница 26: ...elect button on the lower section of the screen 5 The selected unit appears on the Selected unit section on the top of the screen and settings can be changed Unit TAB The Unit TAB allows the user to c...

Страница 27: ...06 SVFT PRS Pressurized Dome Housing Installation 21 Install TAB The Install TAB allows the user to install upgrade newer versions Info Tab The Info TAB displays the selected IP product general inform...

Страница 28: ...he Disable load button allows the pausing of the application load in case of software issues while still permitting communication via VNSetup the Enable load button resumes the application load After...

Страница 29: ...nected to the network that it is active and that it is configured to use the same Nucleus 2 From the workstation desktop run the ViconNet application 3 After logging in open the site setup selection w...

Страница 30: ...efer to the ViconNet workstation manual XX113 for complete information on operation A copy of the manual can be found on the CD included Uninstalling If it becomes necessary to uninstall to SVFT PRS f...

Страница 31: ......

Страница 32: ...disappear the SurveyorVFT is not communicating with the control device Verify that the SurveyorVFT address is selected on the control device Sometimes moving the joystick can begin communication If co...

Страница 33: ...opropyl alcohol and water using a lint free soft paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft clea...

Страница 34: ...m countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following informati...

Страница 35: ...ideo quality with increased difficulty in handling and installation Use the required picture quality and cable distance to provide a guide in choosing the best cable type For cables other than the app...

Страница 36: ...d twisted pair in a single jacket This configuration is the most convenient for RS 422 RS485 applications Single twisted pair is also a suitable cable Choose a Belden cable type by referring to the ch...

Страница 37: ...most commonly used cable types are CAT5 CAT5e and CAT6 These category cables are best suited for Ethernet network applications Choose a Belden cable type by referring to the characteristics listed be...

Страница 38: ...coax UTP fiber 2 3 A ViconNet Power 44 W with SurveyorVFT coax UTP fiber 54 W ViconNet Heat Equivalent 2 5 btu min 0 6 kg cal min with SurveyorVFT coax UTP fiber 3 1 btu min 0 77 kg cal min ViconNet...

Страница 39: ...another tour and save recall camera status Autotour Capabilities 2 autotours available with 256 pan tilt and zoom functions per autotour Programming is done in real time with joystick and push button...

Страница 40: ...tilt 0 125 zoom 0 125X Competitive Protocols DIP Switch selectable Available in coaxial and UTP versions only Protocols are Pelco Pelco D Protocol 3 2 99 RS 485 N 8 1 simplex 2400 bps duplex 4800 bps...

Страница 41: ...pipe mounting brackets purchased separately Cable Access 1 09 in 28 mm hole size utilizing provided 0 75 in 19 mm liquid tight fitting Mounting Pattern Four 4 hole pattern sized to accommodate provide...

Страница 42: ...fault when the pressure in the housing dips below 1 psg an On Screen Display message appears stating Low Pressure Alternatively this alarm warning may be sent to the CPU by enabling the alarm in the C...

Страница 43: ...Company and the return shipment is prepaid in accordance with policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the C...

Страница 44: ...rters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712 8781 Far E...

Отзывы: