Vicon SMS Enterprise Скачать руководство пользователя страница 12

9

 

Migrating from a Basic Network Controller to an Enterprise 
Network Controller 

If you are upgrading your solid-state, basic Network Controller system by migrating to a disk-based 
Enterprise or Enterprise Ultra, complete the following procedures. You will need to replace the 
Controller/Node blade circuit card that is currently in your solid-state system with a Node-only card. 

 

Back up the Your data from the current system 

1.  Login to the current system. 

2. Select 

Administration : Utility : Backup System

3.  Enter a comment to explain the purpose of this backup. 

4. Click 

Full Backup

5.  When the backup is complete it is listed in the 

Existing Backups

 section.  

6.  Download a copy of this backup to a disk drive by clicking the get link in the 

Download?

 

column. 

7.  In the File Download dialog click 

Save

8.  In the Save As dialog browse to the location where you wish to save this backup. 

9. Click 

Save

 

Replace the solid-state Network Controller/Network Node with a Node-only blade 

1. Select 

Setup : Site Settings : Network Nodes

2. From 

the 

Name

 drop-down select the Node that you will replace. 

3.  Write down the Node name and Unique Identifier for this node. You will need to know this 

later to complete your configuration. 

4. Select 

Setup : System Maintenance : Utilities

.  

5. Click 

the 

Shutdown Now

 button in the 

System Functions

 section of this page. 

6.  Please wait for the system countdown to complete and you will hear two beeps. 

7.  Remove power from the system. 

8.  Replace the Controller/node blade with a Node-only blade. 

9.  Re-power the now Node-only system. 

NOTE

: By default, nodes come from the factory set to DHCP.  

 

Start the Enterprise or Enterprise Ultra Network Controller and restore the data backup 

NOTE

: If you set your Enterprise IP settings to the same settings as the previous controller 

then router settings, port forwarding settings, and Node auto-discovery settings will not need 
to be changed. 

1.  Connect power and the network to the Enterprise Network Controller. 

2.  Open the drive door on the front panel of the Enterprise controller and press the power 

switch. The system may need 2 to 3 minutes to launch. 

3.  Open your browser and enter the Enterprise IP address into the address line. Press the Enter 

key.  

Содержание SMS Enterprise

Страница 1: ...precisely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2009 Vicon Industries Inc All rights reserved Product specifications subject to change without notice VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Ho...

Страница 2: ......

Страница 3: ...in tight spaces where they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent damage due to lightning and power line surges 13 Power Lines Do not locate outside cables over power or utility lines where they can fall and make direct contact Contact with power...

Страница 4: ...rise Network Controller 2 Configuring IP Settings 3 Logging in to your Network Controller 4 Connecting Nodes and Configuring System Resources 4 Specifications 6 Front Panel LEDs 6 Reset Switches and Drive Lights 7 Hard Drives 8 Migrating from a Basic Network Controller to an Enterprise Network Controller 9 ...

Страница 5: ...images below 2 Connect the network cable to the network connector on the back of the Enterprise or Enterprise Ultra Network Controller Be sure the place the cable in the correct connector as shown below The back panel of the Enterprise Network Controller 1U rack mount The back panel of the Enterprise Ultra Network Controller 2U rack mount 3 For the Enterprise Ultra 2U open the drive door on the fr...

Страница 6: ...Network Controller and click the link in the Initmode Settings section 2 You can edit any of the settings on this page NOTE If you change the IP address of the Network Controller be sure to take note of the new address as you will need it to log in later 3 In the Initmode Settings section select No from the drop down This ensures that Init mode will not redisplay when you reboot You can redisplay ...

Страница 7: ...the screen 6 Beneath the Current value next to the New value prompt enter the new value for this setting and press Enter 7 Use the arrow keys to move the highlight down to Save changes and press Enter The IP setting changes that you have made are now saved to the Network Controller 8 Repeat steps 5 through 8 to make any further changes to the Network Controller IP settings 9 Use the arrow keys to ...

Страница 8: ...cedure and ensure that all nodes are enabled 10 If some nodes still will not connect it may be necessary to adjust port forwarding on routers and gateways to allow the nodes on different subnets to communicate with the controller See Tech Note 1 for details NOTE It may also be necessary to use nnconfig exe to assign a specific controller IP address to each remote node rather than to allow nodes to...

Страница 9: ...ons of the LEDs Inside the Enterprise Network Controller front cover The front panel of the Enterprise Ultra controller has LEDs connector ports and a lockable hard drive door The table beneath explains the functions of the LEDs HDD TEMP FAN POWER Drive door Lock The front plate of the Enterprise Ultra Network Controller POWER On Green Power is supplied to the unit On Red Redundant power supply fa...

Страница 10: ...reen Drive OK Off or On Red Drive failure System Reset This button restarts the Network Controller processes Alarm Reset The Network Controller has an audible alarm which sounds when the power temperature or the fan are in an abnormal state Press this to stop the audible alarm Power Press and hold for 3 to 5 seconds to force a power off NOTE It is not recommended that the unit be powered down in t...

Страница 11: ...he Enterprise Ultra to perform this operation The Enterprise Ultra will continue to perform its access control functions throughout this process 6 Open the lockable drive door 7 Slide the drive lock switch to the left See image below 8 Place a finger into the gap to the right of the drive lock switch and pry the drive removal lever out and to the right This will unseat the drive 9 Pull the drive o...

Страница 12: ...ngs Network Nodes 2 From the Name drop down select the Node that you will replace 3 Write down the Node name and Unique Identifier for this node You will need to know this later to complete your configuration 4 Select Setup System Maintenance Utilities 5 Click the Shutdown Now button in the System Functions section of this page 6 Please wait for the system countdown to complete and you will hear t...

Страница 13: ...6 In the dialog box select from the drop down the newly installed node NOTE If other nodes are powered you may need to know the Unique identifier for this new node to make the correct selection You can use nnconfig exe to get this UID 7 Click Save and confirm the swap in the popup NOTE Since resources inputs outputs readers etc are specific to a node unique identifier the Swap you performed in thi...

Страница 14: ...may also be necessary to use nnconfig exe to assign a specific controller IP address to each remote node rather than to allow nodes to Auto Discover the controller 10 Test system access control functions Backup the Enterprise controller 1 Select Administration Utility Backup System 2 Enter a Comment to explain the purpose of this backup 3 Click Full Backup 4 When the backup is complete it is liste...

Страница 15: ...amage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued...

Страница 16: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...