background image

Vicon Lock+ 

Quick Start Guide

Connect. Integrate. Synchronize.

Содержание Lock+

Страница 1: ...Vicon Lock Quick Start Guide Connect Integrate Synchronize ...

Страница 2: ...ameras Lock features Timecode and genlock Support of VESA standards Connection to third party analog devices Remotely triggered start and stop General Purpose Input and Output GPIO sockets for synchronizing external devices Lock front view Lock rear view 1 2 3 4 5 6 7 8 10 9 Vicon logo illuminates to indicate status Color Status Red Booting Green Booted but not connected Blue Communicating with so...

Страница 3: ...nal including Vertical Interval Timecode VITC from the master video source to the Lock and any other synchronized video or audio devices in a chain The Lock must be genlocked to this external video source Important If the Lock is the last device in the chain the Ref Loop connection that is not being used for signal output must be terminated in 75 Ω remotely or by using a 75 Ω terminator 5 Timecode...

Страница 4: ...cables into the required connector Pin assignment 35 66 72 16 57 5 6 277 6 5 5 9 5 5 62 5 386 1 7 558 386 1 5 6 72 2 5 The following illustration shows the pin assignment of the Weidmüller connectors 723 9 3 1 3 1 3 1 3 1 5 5 9 3 1 0 5 1 Note that the pins shown in the illustration left are assigned as follows Pins 1 8 top row Ground Pins 9 16 bottom row Signal inputs In this diagram the bottom of...

Страница 5: ...card Ethernet cable 1 per camera Optical data Ethernet Vantage cameras Up to 14 on 26 port PoE Important PC specification correct at time of publication but may now be superseded For the most up to date information search for PC specification on the Vicon website Vicon Lock in a Vicon Vantage system ...

Страница 6: ...terference Causing Equipment Regulations for Canadian customers Conformity to the Canadian Interference Causing Equipment Regulations This Class A digital apparatus meets the requirements of the Canadian Interference Causing Equipment Regulations ICES 003 2004 Avis de conformité à la réglementation d Industrie Canada Cet appareil numérique de la classe A respecte toutes les exigences du Règlement ...

Страница 7: ... essential performance of medical electrical equipment Not suitable for use in high magnetic flux ionising radiation sterile or life or safety critical environments Product configurations and software options Conformity of the Metrological Performance of CLASS 1 Products Manufactured in Accordance with Annex VII Section 5 of the Medical Devices Directive 93 42 EEC of the 14th June 1993 We Vicon Mo...

Страница 8: ... Motion Systems Ltd Vicon is a registered trademark of Oxford Metrics plc Vicon Blade Vicon Bonita Vicon Lock Vicon Nexus Vicon Tracker Vicon Vantage Vicon Vero aand Vicon Vue are trademarks of Oxford Metrics plc VESA is a registered trademark owned by VESA www vesa org about vesa Portions of the software were initially developed by Lucent Technologies Inc and are subject to the terms of Lucent Pu...

Отзывы: