![Vicon AURORA 2000 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/vicon/aurora-2000/aurora-2000_quick-manual_1012799006.webp)
Quick Guide
Connections
2
Vicon Industries Inc. 89 Arkay Drive, Hauppauge, NY 11788
VIDEO OUT
Up to 9
units per
DL.
V1400X-IDL
V1400X-IDL
Dome
Rcvr.
Pin No.
Signal
Alarm 1-16
Normally open dry contact alarm
Ground
Dry contact alarm common
Normally closed dry contact alarm
1-16
19
20-35
36
37
1
1
1
1
1
PC Serial
Port
AurorA200 Signal
Pin No.
VCR Clock In
Ground
Aux Alarm Out
Ground
1
2
3
4
Terminate with 75 ohms at the destination
devices. Refer to the labels for outputs 9-16.
There are two labels on each cable. Use the
"A2K Video" label instead of the "Video" label.
Cable supplied by
installer or purchased
in AurorA2000 prepacs.
A2K
Video
1/9
A2K
Video
2/10
A2K
Video
3/11
A2K
Video
4/12
A2K
Video
5/13
A2K
Video
6/14
A2K
Video
7/15
A2K
Video
8/16
Camera
Alarm Devices
15
13
16
14
11
9
12
10
ALARM
LOOPING 2
OUTPUT
ONL
Y
L
N
E
COM1
VCR
COM2
Cable supplied
by installer.
110 and 220
cables supplied
in accessory kit.
Connector and pins
supplied in accessory kit.
RD
BK
OR
BL
W
BR
YL
G
RS-485
Data +
N.C.
Ground
Keyboard
Clock
+5 V Out
Keyboard
Data
N.C.
RS-485
Data–
RD
BK
OR
BL
W
BR
YL
G
Ground
Keyboard
Clock
+5 V Out
Keyboard
Data
RS-422
Comm Out –
RS-422
Resp In –
RS-422 Resp In +
or RS-232 RxD
RS-422 Comm Out +
or RS-232 TxD
AurorANet Termination Box