FMC-PS Installation and Operation │
3
Installation
InstallatIon ConsIderatIons
This power supply is supplied as a rack module only. Units should be installed in dry locations protected from
extremes of temperature and humidity.
Unit is to be installed only in the FMC-RK Card Cage.
WarnInG:
Before installing, be sure that the power supply is turned off and that the rack power supply is
disconnected from any power source.
1. Make sure that the power supply is oriented right side up, and slide it into the card guides in the rack until
the power supply’s front panel sits flush against the front of the card cage.
CaUtIon:
Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the power supply is seated against the
front of the rack.
3. Connect the wires to the electrical connector on the back of the card cage. Connect supplied AC line cord to
power connector in the rear of the power supply.
I
MPortant saFeGUards:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should
be given to installing the equipment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.