3.1.6 Fastening the protection box
Choose the location for the protection box.
The protection box can be mounted on a concrete
wall or, whenever possible, directly onto the
structure of the stator or machine casing.
Figure 6 : Mounting holes
location
Mounting a protection box
on the stator
or
machine casing:
1. Drill (refer to
and thread into the structure (refer to
“Fastening the ABS protection box on steel”
2. Fasten the protection box as shown.
Figure 7 : Fastening the ABS protection box on steel
13.19'' [335mm]
4.00'' [102mm]
PROTECTION BOX
ON STEEL
HOLE: DRILL BIT 5mm (13/64'')
TAP DRILL 1/4-20 or M6-1.00
DEPTH: 19mm (3/4'')
1/4''-20 x 5/8'' BOLT
or
M6-1.00x16mm BOLT
LOCKWASHER
WASHER
ANTI-VIBRATION MOUNT
SCREW 10/32 x1/2
LOCKWASHER 10/32
WASHER 10/32