Chapter 4
1PPS Wander Analysis
Measuring TIE and calculating MTIE/TDEV
T-BERD/MTS 5800 Timing Expansion Module User Manual
Page 42
22112315, Rev. 004
July 2017
be lost too. If you want use a GNSS tuned oscillator to perform measurements at a loca-
tion
without a GNSS synchronization source
, you must use the
1 PPS OUT
connector
on the TEM to provide the GNSS derived reference signal to the
1 PPS IN 1
connector.
To use a GNSS tuned oscillator as a reference signal
1
Before traveling to a location without a GNSS synchronization source, place the
oscillator into holdover mode (see
“Forcing the oscillator into holdover mode” on
2
After you reach the location (and are ready to begin 1 PPS analysis), use a cable
to provide a signal from the
1 PPS OUT
connector to the
1 PPS IN 1
connector.
3
When you configure the TEM for 1 PPS Analysis (see
“Analyzing 1PPS wander” on page 44
certain to select
1 PPS IN 1
as the configuration on the Oscillator/Timing setup
tab. This indicates that the reference signal is provided by the
1 PPS IN 1
connector.
4
Connect the cable providing the signal to be analyzed to the TEM connector
labeled
1 PPS IN 2
.
The reference signal (provided by the GNSS tuned oscillator in holdover mode) is now
provided via the
1 PPS IN 1
connector on the TEM.
Measuring TIE and calculating MTIE/TDEV
Measuring TIE and calculating MTIE/TDEV involves ensuring that the TEM is placed
into 1PPS Analysis mode, then enabling and specifying pass and fail thresholds for the
maximum allowable time offset, maximum allowable MTIE, and minimum and
maximum allowable TIE. The Event Log will log an event and timestamp each time a
measurement exceeds the threshold that you specified, and the Summary result pane
will change to red to indicate that a threshold was exceeded. Reports will also indicate
that the test passed or failed for each enabled threshold.
To measure TIE and calculate MTIE/TDEV
1
Verify that the TEM oscillator has been turned on, and that it has warmed up. For
details, see
“Turning on the Rubidium Oscillator” on page 14
.
2
Select the
Timing Module
tab, then select the
Setup
soft key.
3
On the left of the screen, select
Oscillator/Timing
.
The
Oscillator/Timing
setup tab appears.
NOTE:
The time it takes to update the TIE data or calculate MTIE/TDEV depends on
the amount of data collected.