11
© 2020 Viavi Solutions Inc.
Sweep Settings
•
Forward Telemetry Frequency
– Sets the downstream telemetry signal frequency – this will need to be set in the
field sweep unit (ONX or DSAM) to be able to communicate with the SCU-1800
•
Independently set the transmit level of the telemetry signal and transmit level of sweep pulses
– if the telemetry
signal is set in the diplex rolloff then the transmit level may need to be increased to overcome the attenuation of
the system diplexers
•
Reverse Telemetry Frequency
– Sets the upstream telemetry signal frequency – this will be communicated to the
field sweep unit (ONX or DSAM) in the forward telemetry to enable bi-directional communication
•
Rapid Reverse Sweep Capable
– If enabled will instruct capable ONXs to use the Rapid Reverse Sweep method
•
Automatically start sweep at power on
– If enabled will activate sweep based on previously set configuraitons
when power is restored to the SCU-1800