Thank you for purchasing the Visual Fault Locator.
Visual Fault Locator
User Manual
Operation Procedures
Installing the Batteries
Overview
The
Visual Fault Locator
(VFL)
is a ruggedized, hand-
held tool used to locate breaks and/or damages in optical
fibers. It employs a powerful red laser designed to couple
to optical connectors, giving you the ability to locate areas
in a fiber that have been damaged, broken or tightly bent.
The laser light will escape from the fiber at the exact site of
the damage, causing the cable sheath to illuminate red. The
FLASH
control allows the option for continuous illumination
or flashing mode.
This manual will provide the necessary information to
properly operate the VFL.
1. Remove the
Battery Cap
.
2. Insert 2 “AA” batteries with the
positive (+) end facing the inside
of the VFL.
3. Reattach the
Battery Cap
.
4. Turn the power
ON
to verify
proper installation
(the red power
LED will illuminate)
.
1. Pull off the dust cover and attach a 2.5mm connector (or use
the 1.25mm adapter to attach a 1.25mm connnector) to the
connector input on top of the unit.
2. Turn the VFL ON by pushing the
ON/OFF button
(the red
power LED will illuminate)
.
3. If there is damage to the fiber, a red illumination will appear
at the exact location of the damage. For easier identification,
push the
FLASH
button to activate the flashing-mode
(the
red power LED will begin to flash)
. Push the
FLASH
button
again to return to continuous-mode.
4. When finished, be sure to turn the unit
OFF
to conserve
battery life.
Controls
Assembly
The
Visual Fault Locator
is fully assembled and comes
with a soft-sided carrying case. Included are 2 “AA” batteries
with > 80 hours of continuous-mode battery life. To install
the batteries, follow the battery installation procedure
below.
The VFL is equipped with a 2.5mm interface for compatibility
with connectors such as SC, ST and FC, while the 1.25mm
adapter (included) enables compatibility with small form
factor connectors such as LC and MU.
ON/OFF Button
The ON/OFF button acts as the
power switch.
FLASH Button
The FLASH button allows the user
to switch between continuous
laser light and flashing laser light.
Positive (+)
End
“AA” Battery
Battery Cap
CAUTION!
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
laser light exposure.
Never look directly into the VFL laser output.
Cover the VFL output with the dust cap when not in use.
Do not magnify or otherwise modify the laser output.
LASER LIGHT
DO NOT STARE INTO BEAM OR VIEW
DIRECTLY WITH OPTICAL INSTRUMENTS
1mW @ 630–670nm
IEC CLASS 2M LASER PRODUCT
DCRH CLASS II LASER PRODUCT
Note:
Diode laser power up to 1mW at 650nm can be accessible in a 7mm
aperture at 100mm.
© 2017 Viavi Solutions Inc.
Product specifications and descriptions in this
document are subject to change without notice.
Vfl-sg-fit-nse-ae
30186100 900 0517