VIAVI Solutions
Connect to Fiber Under Test (FUT):
All fibers and connectors should be inspected and clean prior to connection, as described on page 1.
The COSA-4055 is typically connected to the FUT via a Monitor Port or splitter/tap to not disrupt
service. The COSA-4055 can also be directly connected to the common port or common fiber via a
coupler during turn up or maintenance:
Figure 4: Connecting to Monitor Port
Figure 5: Connecting to common cable
1.
Inspect the COSA-4055 port on top of the test set.
2.
If connecting to the
Common Cable
, connect the
Common Cable
to an optical coupler with the
same connector type and inspect the fiber end face in the coupler.
3.
If connecting to the
Monitor Port
or
Common Port
on the Mux, inspect the Mux Port.
4.
Inspect the fiber end face of the Launch Cable.
5.
Connect the
Launch Cable
to the COSA-4055 port.
6.
Inspect the other fiber end face of the Launch Cable.
7.
Connect the
Launch Cable
to the coupler or Mux port
.