For 1 jumper single-ended loopback,
1.
Connect the FC and SC ends of the reference cord to the TX port RX port of the
adapter respectively.
Please ensure the fiber cables are cleaned using the cleaning kit provided in the kit.
TX
FC1
SC1
RX
2.
Press the SETUP button > Testing Configuration and select “One Jumper” from
Single-Ended column. Select Single or Bi direction depending on requirement.
3.
Press the TOOLS button > Set Reference and press the “ok” button to begin set
reference.
4.
Check that the Set Reference result is ≤0.15 dB before proceeding. Clean or replace
reference cords if necessary, and set reference again if value exceeds 0.15 dB.