Stop using this monitor and consult your physician if you

experience skin irritation or discomfort.

Consult your physician before using this monitor on an arm

with an arterio-venous (A-V) shunt.

Consult your physician before using this monitor if you have

had a mastectomy or lymph node clearance.

Consult your physician before using the monitor if you have

severe blood flow problems or blood disorders as cuff inflation

can cause bruising.

People who have a severe circulatory deficit in the arm must

consult a physician before using the device, to avoid medical

problems.

Do not self-diagnose the measurement results and start

treatment by yourself. Always consult your physician for

evaluation of the results and treatment.

Do not apply the cuff on the injured arm or the arm under

medical treatment.

Do not apply the cuff on an arm while on an intravenous drip

or blood transfusion.

Do not use the device with other medical electrical (ME)

equipment simultaneously.

Do not use the device where flammable gases such as

anesthetic gases are present. It may cause an explosion.

Do not use the device in the area of HF surgical equipment,

MRI, or CT scanner, or in an oxygen rich environment.

Use only the approved arm cuff for this device. Use of other

arm cuffs may result in incorrect measurement results.

Rest for at least 5 minutes before taking the measurement.

Remove tight-fitting or thick clothing from your arm while

taking a measurement.

Remain still and do not talk while taking a measurement.

If the patients’ arm is outside the specified circumference

range (22-42cm) that may result in incorrect measurement

results.

The device is not intended for use with neonatal, pregnant,

including pre-eclamptic, patients.

Do not use the device in a moving vehicle (car, airplane).

When choosing a third party charging adaptor, select one that

complies with IEC 60950 or IEC 60601-1.

Содержание AirBP BP1

Страница 1: ...lood Pressure Monitor User Manual Model BP1 BP1A BP1S BP1SA BP1B BP1C Download Phone App AirBP iOS App Store Android Google Play Note if you ve downloaded the app before please update it to the latest version ...

Страница 2: ...nts 1 The Basics 1 2 Introduction 3 3 Using the Monitor 6 4 Accessories 12 5 Specifications 13 6 Maintenance and Cleaning 14 7 FCC Statement 16 8 Reference to Standards 17 9 Electromagnetic Compatibility 19 ...

Страница 3: ...n with moisture or a location where water may splash on the device This may damage the device Measurements may be distorted if the device is used close to television microwave oven cellular telephone X ray or other devices with strong electrical fields Sources of electromagnetic disturbance may affect this device e g mobile telephones microwave cookers diathermy lithotripsy electrocautery RFID ele...

Страница 4: ... arm while on an intravenous drip or blood transfusion Do not use the device with other medical electrical ME equipment simultaneously Do not use the device where flammable gases such as anesthetic gases are present It may cause an explosion Do not use the device in the area of HF surgical equipment MRI or CT scanner or in an oxygen rich environment Use only the approved arm cuff for this device U...

Страница 5: ... 2 Introduction 1 1 Device Description The blood pressure monitor includes 6 models including BP1 BP1A BP1S BP1SA BP1B and BP1C The difference is shown as the table Items BP1 BP1A BP1S BP1SA BP1B BP1C Screen Bluetooth Color of Enclosure Bright silver Dark silver Bright silver Dark silver Blue gray Dark green The blood pressure monitor includes six models BP1 BP1A BP1S BP1SA BP1B and BP1C It uses t...

Страница 6: ...d pressures and pulse rate for adult population in home and hospital facilities by using a non invasive oscillometric technique with a single upper arm cuff 22 42 cm The device detects the appearance of irregular heart beats during measurement and gives a warning signal with readings 1 3 Contraindications This device is contraindicated for use in ambulatory environments This device is contraindica...

Страница 7: ...stproof and waterproof level Follow operating instructions MR Unsafe keep away from magnetic resonance imaging MRI equipment CE marking Authorized representative in the European community This product complies with the rules and regulations of the Federal Communication Commission Stop pumping Pulse rate Power off Battery low Charging ...

Страница 8: ...fore please update to the latest version 3 1 Charge the Battery Charge the monitor by using the USB cable to connect a USB charger or to the PC USB Port A fully charge takes 2 hours Note The device cannot be used during charging 3 2 Applying the Arm Cuff Do not roll up shirtsleeve tightly 1 2cm Artery position mark ...

Страница 9: ...e artery 3 3 How to Sit Correctly To take a measurement you need to be relaxed and comfortably seated Sit in a chair with your legs uncrossed and your feet flat on the floor Sit with your back and arm being supported Place your arm on a table so the cuff is level with your heart 3 4 Single machine measurement Press the power button to start the machine and enter the interface of waiting for measur...

Страница 10: ... AirBP on your smartphone App will search the device Choose your device AirBP xxxx in App Note Keep the distance between monitor and phone within 1 5 meter DO NOT pair in your phone settings The APP can be downloaded in Google Play or APP Store with the name AirBP which requires a smartphone 3 6 Measurement Make sure your phone voice is turned on and the volume is loud enough Follow the text and v...

Страница 11: ... the instruction hold the bulb with no squeeze or pressing waiting for the next instruction In some cases if the App judged that the pressure in the cuff is not high enough for the measurement then an instruction of pump again will be issued Note During the measurement you should keep still Otherwise the blood pressure readings may be inaccurate Stop pumping when the indicator blue red blinks pres...

Страница 12: ...nt the monitor will automatically deflate the cuff slowly and it takes less than 30s for finishing the whole automatic deflation On result page you can add the user name or ID help you manage multiple users data add note share the results or delete it If the monitor detects the irregular heartbeat and the corresponding symbol will display below to the PR value Note The device turns off automatical...

Страница 13: ...11 19 3 8 Review the history In App History you can check the history list You can select a specific ID or All ...

Страница 14: ... a compatible phone The monitor doesn t response to the button press The monitor is running in an unexpected status Reset the device by press and hold the button for 5s Cannot get blood pressure readings The measurement is interrupted by arm movement or unexpected bulb squeeze Keep arm still and don t squeeze the bulb during deflating measure phase There is an over leakage of press Check if the ho...

Страница 15: ...Physical Size 68mm long 25mm diameter main unit Weight Less than 30 g main unit Cuff size Adult cuff 22 42cm Wireless connectivity Built in Bluetooth 4 0 BLE Power Supply Charge input Micro USB DC5V Battery type Rechargeable lithium polymer battery 3 7Vdc 130mAh Charge time 2 hours Blood Pressure Technology Oscillometric Method Measuring Range 0 299 mmHg DIA Range 40 150 mmHg SYS Range 60 230 mmHg...

Страница 16: ...d the components in a clean safe location Do not wash the device and any components or immerse them in water Do not disassemble or attempt to repair the device or components Do not expose the device to extreme temperatures humidity dust or direct sunlight The cuff contains a sensitive air tight bubble Handle this carefully and avoid all types of straining through twisting or buckling Clean the dev...

Страница 17: ...loth with 70 alcohol Do not use petrol thinners or similar solvent Clean the cuff carefully with cloth soaked 70 alcohol The cuff must not be washed Clean on the monitor and the arm cuff and then let it air dry 6 3 Disposal Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations not with domestics waste ...

Страница 18: ... uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on...

Страница 19: ...EC60601 1 2005 A1 2012 IEC60601 1 2 2014 IEC EN60601 1 11 2015 IEC80601 2 30 2009 A1 2013 ISO81060 2 2013 FCC part 15 Plot of DBP difference between the paired blood pressure determinations against the reference diastolic measurement ...

Страница 20: ...al test applies for the BP1S device with one cuff size comparing with Mercury sphygmomanometer The result met the criteria specified in ISO 81060 2 2013 In addition there were no reported adverse effects during these investigations Plot of SBP difference between the paired blood pressure determinations against the reference systolic measurement ...

Страница 21: ... though they meet the requirements of CISPR When the inputted signal is below the minimum amplitude provided in technical specifications erroneous measurements could result Portable and mobile communication equipment may affect the performance of this device Other devices that have RF transmitter or source may affect this device e g cell phones PDAs and PCs with wireless function EMC table informa...

Отзывы: