Hxx-QS-HB-3 VialiteHD Quick Start Guide 

Page 2

 

CR3134 

Standard Optical Connectors and Fibres 

Ensure that all mating connectors are matched types.   

 

To connect SC/APC optical connectors, remove the connector protective cover.  Align the connector keyway slot in the adaptor  to the key of the plug.  Gently push 
the plug into the adapter until a click is heard and the connector locks.  To disconnect, grip the body of the plug and gently pull the plug from the adaptor, replace the 
protective cover. 

 

To connect E2000/APC optical connectors.  Gently push the plug into the adapter until a click is heard and the connector locks.  To disconnect, depress the lever of 
the plug and withdraw the connector.  The protective cover engages and disengages automatically. 

 

To connect LC/APC optical connectors, remove the connector protective cover.  Gently push the plug into the adapter until a click is heard and the connector locks.  
To disconnect, depress the lever of the plug and withdraw the connector, replace the protective cover. 

 

All PPM FC/APC equipment use narrow key FC/APC connectors, these are not compatible with wide key FC/APC.  To connect FC/APC optical connectors, remove 
the protective cover and align the white ceramic centre ferrule on the cable connector with the mating receptacle.  There is  a key on the side of the ferrule, which 
must match the keyway slot in the receptacle shroud.  When they are aligned, gently push the plug home and finger tighten the knurled collet nut onto the threaded 
receptacle.  Disconnection is the reverse of connection; replace the protective covers on both the receptacle and the cable plug. 

Minimum Bend Radius of a simplex patch cable is typically 30mm, at this radius there will be a very small increase in loss due to the bend (~0.05dB) 
 

Connecting and Disconnecting RF Connectors 

This product uses a range of RF connectors.  Please ensure that RF connections are made with correctly matched connectors and cable impedances.  Failure to do so 
may  result  in  damage  to  the  connectors  and  loss  of  performance.    SMA  RF  connectors  should  only  be  connected  with  a  calibrated  SMA  torque  spanner.    BNC 
connectors are available in both 50 and 75 ohms.  
 

RF Module Input/Outputs Levels 

 

RF inputs and outputs should not be exposed to DC voltage levels in excess of ±36V. 

 

Absolute maximum no damage RF input level is +13dBm (some units will tolerate more, see handbook). 

 

Absolute maximum no damage RF level applied to an RF output is +13dBm. 

Some  transmitter  modules  are  pre-configured  to  have  a  DC  voltage  present  on  the  RF  input  connector,  to  drive  low  noise  amplifiers  and  similar  equipment.    Check 
module  handbook  and  description  for  more  details.    All  receiver  modules  will  create  a  1-

2Vpeak  DC  transient  from  the  RF  output  at  start  up  into  a  50Ω  load 

(approximately 5V into a 1MΩ load).  This may cause failure in some very sensitive spectrum analyzers or similar equipment.  All modules have AC coupled inputs and/or 
outputs and will be sensitive to large transients (>5V) applied to either input or output.  This may result in permanent damage to the units, particularly to low frequency 
units.  Contact PPM for more details.  Some receiver modules are equipped with DC loads on their outputs, please see module handbook. 

 
19 Inch Rack Installation 

The 

ViaLiteHD

 

19” Rack Case is designed to fit 19” cabinets.  Two options are available that occupy a height of either 1U or 3U; both have flanges for cabinet mounting.  

The 3U rack case provides mounting for 16 modules, 13 general purpose slots (1-13), 1 dedicated controller slot (14) and 2 dedicated power supply slots (15,16).  The 
3U Rack Case must be used with at least one plug-in HPS Power Supply Module, power inputs are situated at the rear of the rack with one dedicated power connection 
per module.  The backplane contains 9-way D-type data connectors for each module position 1-13; this provides user access to module data.  The rack case provides 
two 50 way connectors (SCSI-3 Har-mik® female) that give access to power, alarm and rack data.  The mating SCSI-3 connector can be terminated with either a ribbon 
or individual round cable, contact PPM for more details.  The pin-outs of these connectors are given in the following section.  Either power supply position can be used; 
the power supplies are designed to current share, if more than 1 is fitted.  If power supplies are operating in redundant configuration, there should be a minimum load of 
20 watts to ensure that both power supplies are active, below this level one power supply may be in idle mode.  A dummy load  board can be supplied, to fit into any of 
the unused slots. 
 
The 1U rack case provides 3 slots and 1 power supply draw.  These slots can be factory configured either for 3 general purpose slots (1-3) or for 2 general purpose slots 
(1-2) plus 1 controller slot (3).  The 1U rack case provides two 25 way standard density D connectors that give access to power, alarm, module data and rack data.  The 
pin-outs of these connectors are given in the following section.   
 

 

Hot swappable 
modules 

Slot 1-13 

General Purpose 

Modules 

Slot 14 

Controller 

Module 

Handle 

Slots 15-16 

Power Supply 

Modules 

Guide Pin 

PSU Power Connection

 

IEC60320/C13 

Rack Connector J1 

Module Data Connector 

Blindmate  

Optical  

Interface 

Handle Release  
Button 

Test Port A 

Test Port B 

Status LED1 

Status LED2 

Status LED3 

Rack Connector J4 

Fully Enclosed Fan 

Fan Power 

Connector 

Blindmate  

Plates 

Standard  

Modules 

Mounting flange 

Blindmate  

RF  

Interface 

Standard  

Optical  

Interface 

Standard  

RF  

Interface 

Controller Optical  

Interface (Optional) 

Controller Rear 
2xRJ45 Ethernet 
Interface  

Controller Front 

RJ45 Ethernet  

Interface 

PSU Status LED 

Controller Craft Port 

Controller Reset 

Button 

Removable 

Fan Cassette 

Содержание Hxx-QS-HB-3 Series

Страница 1: ...cautions Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument Never leave equipment with radiating bare fibres always cap the connectors Do not remove equipment external covers when operating ViaLiteHD and ViaLite Classic compatibility The RF and optical interfaces of ViaLiteHD and ViaLite Classic are compatible Hence it i...

Страница 2: ...rom the RF output at start up into a 50Ω load approximately 5V into a 1MΩ load This may cause failure in some very sensitive spectrum analyzers or similar equipment All modules have AC coupled inputs and or outputs and will be sensitive to large transients 5V applied to either input or output This may result in permanent damage to the units particularly to low frequency units Contact PPM for more ...

Страница 3: ...ly pulling the top of the handle forwards Remove the protective cover from the modules optical connectors Clean the module optical connector Align the module so that the PCB slides into the crow s feet with the module upright and perpendicular to the front face of the rack Gently push the module down its guide applying pressure via the handle as the module is fully mated the top of the handle shou...

Страница 4: ...LED If any LED is RED or FLASHING RED then check fibre connections for cleanliness and that they are correctly fitted If this does not remover the RED LED s then consult the full detailed manual HRx HB or HRK HB for the comprehensive fault finding procedure 6 Connect all RF cables to the RF connectors on the rack cards 7 Allow the equipment to warm up for 15 minutes 8 Ensure that the RF power into...

Отзывы: