background image

 

ViaLite

 quick start guide

 

 

www.vialite.com

 

 

 

Hxx-QS-HB-3 VialiteHD Quick Start Guide 

Page 1

 

CR3134 

PPM 

ViaLiteHD

 Quick Start Guide 

 
This  quick  start  guide  is  intended  as  an  information  summary,  the  relevant  equipment 
handbook should always be treated as the master document. 
 
Initial Inspection 

Unpack and inspect the equipment as soon as possible. If there is any sign of damage or any parts missing, do not install the equipment before seeking advice from PPM 
or  your local agent.  The  equipment received should match the delivery note  that is shipped  with the equipment.   If  there are  any  discrepancies,  contact PPM or  your 
local agent. 

 
Electrical Safety 

ViaLiteHD

 HPS Power Supply Units are Safety Class 1 products (having metal case directly connected to earth via the power supply cable).  The unit is 

also fitted with an earthing/grounding stud connected to the power supply earth.  When operating the equipment note the following precautions: 

 

Hazardous voltages exist within the equipment.  There are no user serviceable parts inside; the covers should only be removed by qualified technician. 

 

The equipment does not have a mains isolating switch.  Equipment must be installed within easy reach of a dual pole mains isolation switch. 

 

There are no user replaceable fuses in the rack mounted equipment.  Replacement should only be carried out by a PPM technician. 

 
ESD Precautions 

Precautions for handling electro-static sensitive devices should be observed when handling all 

ViaLiteHD

 modules.  Technicians should ensure that they 

use  effective  personal  grounding (i.e.  ESD wrist strap etc..)  when servicing the equipment.  Any  equipment or tools used should be grounded  to  prevent 
static charge buildup.  Good practice should be observed at all times for reference see relevant standards. 
EN 61340-5-

1, “Protection of Electronic Devices from Electrostatic Phenomena – General Requirements” 

 

Optical Safety 

The 

ViaLiteHD

 RF Transmitter modules contain laser diode sources operating at nominal wavelengths of 1270nm to 1610nm.   

These devices are rated as EN60825-1:1994 CLASS 1 radiation emitting devices.   A class 1 laser is safe under all conditions of normal use. 
When operating the equipment note the following precautions: 

 

Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument. 

 

Never leave equipment with radiating bare fibres 

– always cap the connectors. 

 

Do not remove equipment external covers when operating. 

 

ViaLiteHD

 and 

ViaLite

 Classic compatibility 

The  RF  and  optical  interfaces  of 

ViaLiteHD

  and 

ViaLite

 

Classic

  are  compatible.    Hence  it  is  possible  for  units  of  different  types  to  interwork  and  be  used  to  expand 

existing systems.  However the physical size, mounting systems and control of the units are different, so it will not be possible to mix systems in a single rack or housing.  
Contact PPM for more details.   

 
Cleaning optical connectors 

Optical connectors MUST be cleaned before use.  

Most performance issues are due to dirty fibres

 

For more details please read the cleaning instruction which accompanies the connector cleaning kit.  Details can also be found on the CD supplied with your equipment. 
 

Blindmate Optical and RF Connectors

 

Note  that  the 

ViaLiteHD 

Blindmate  system  will  simultaneously  mate  electrical,  RF  and  optical  backplane  connectors,  so  both  RF  and  optical  connectors  need  to  be 

prepared.  Firstly inspect the rear Blindmating plate, ensure that the connector barrels are fitted into all RF connectors and are centrally aligned.  Remove any protective 
covers from the optical connectors.  Fit the Blindmating plate into the appropriate slot at the rear of the rack.  For module installation see the following section. 
 
Connect  the  external  system  cables  to  optical  and  RF  interfaces.    External  interface  SMA  RF  connectors  should  only  be  connected  with  a  calibrated  SMA  torque 
spanner.  External optical interface SC/APC adaptors are fitted with a sprung protective cover.  To connect SC/APC optical connectors, remove the plug protective cover.  
Open the adaptor sprung cover, align the connector keyway slot in the adaptor to the key of the plug.  Gently push the plug into the adapter until a click is heard and the 
connector locks.  To disconnect, grip the body of the plug and gently pull the plug from the adaptor, replace the protective cover. 

 

Peel the plastic cover from an unused “N” cleaning pad. 

 
- Hold the connector between your thumb and forefinger 
 
 Clean  the  connector  using  firm  pressure  by  swiping  in  a 
pendulum motion through each segment of the “N” shape, 
following the diagram 
 
 
- Do not swipe over the same space twice. 

Содержание Hxx-QS-HB-3 Series

Страница 1: ...cautions Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument Never leave equipment with radiating bare fibres always cap the connectors Do not remove equipment external covers when operating ViaLiteHD and ViaLite Classic compatibility The RF and optical interfaces of ViaLiteHD and ViaLite Classic are compatible Hence it i...

Страница 2: ...rom the RF output at start up into a 50Ω load approximately 5V into a 1MΩ load This may cause failure in some very sensitive spectrum analyzers or similar equipment All modules have AC coupled inputs and or outputs and will be sensitive to large transients 5V applied to either input or output This may result in permanent damage to the units particularly to low frequency units Contact PPM for more ...

Страница 3: ...ly pulling the top of the handle forwards Remove the protective cover from the modules optical connectors Clean the module optical connector Align the module so that the PCB slides into the crow s feet with the module upright and perpendicular to the front face of the rack Gently push the module down its guide applying pressure via the handle as the module is fully mated the top of the handle shou...

Страница 4: ...LED If any LED is RED or FLASHING RED then check fibre connections for cleanliness and that they are correctly fitted If this does not remover the RED LED s then consult the full detailed manual HRx HB or HRK HB for the comprehensive fault finding procedure 6 Connect all RF cables to the RF connectors on the rack cards 7 Allow the equipment to warm up for 15 minutes 8 Ensure that the RF power into...

Отзывы: