background image

IMPORTANT SAFETY INSTRUCTIONS

CAUTION

 - To reduce risk of electrical shock:

- Do not disassemble.  Do not attempt repairs or modifications.  Refer to qualified service agencies 

 

  for all service and repairs.

- Do not use this product in an area where it can fall or be pulled into water or other liquids.

- Do not reach for this product if it has fallen into liquid. 

- Use this compressor with 12-volt DC systems only.

- This product should never be left unattended during use.

WARNING - To prevent injury:

-  Never allow children to operate this compressor.  Close supervision is necessary when this compressor 

  is being used near children.

-  This compressor will become very HOT during and immediately after use.  Do not touch any part of this 

 

  compressor with bare hands during and immediately after use. 

-  Do not use this product near flames or explosive materials or where aerosol products are being used.

-  Do not operate this product where oxygen is being administered. 

-  Do not pump anything other than atmospheric air.

-  Never use this product while sleepy or drowsy.

-  Do not use any tools or attachments without first determining maximum air pressure for that tool 

 

  or attachment.

-  Never point any air nozzle or air sprayer toward another person or any part of the body.

-  This air compressor is equipped with an Automatic Reset Thermal Protector, and can automatically 

 

  restart after the thermal protector resets.  Always cut off power source when thermal protector 

 

  becomes activated.  

-  Wear safety glasses or goggles when operating this product.

-  Use only in well ventilated areas.

INSTALLATION

Please read and follow the installation instructions carefully to avoid injury or damage to the 

compressor and your vehicle.

Each of our air compressors and parts have been carefully produced and packaged.  Before you 

begin installation, please familiarize yourself with Installation Parts List (Fig. 1) of this manual.  

Guidelines for Selecting Mounting Location:

The selection of proper mounting location for your air compressor will help ensure a long and trouble 

free compressor service life. Please pay close attention to the following guidelines: 

1. Select a 

FLAT, UPRIGHT, AND SECURE

 location where the compressor can be mounted.

2. To maximize air compressor performance, locate compressor as CLOSE TO THE BATTERY

 as  

  possible so that length of positive lead wire required is at a minimum.  

3. Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES

  The cooler the ambient temperature, the less chance the compressor will overheat. 

4.  This compressor is moisture & dust resistant, but NOT DIRT OR WATERPROOF

. Do not mount  

  compressor in locations where the unit is likely to come in contact with the elements. 

5. For compressor with remote filter mounting, select compressor’s mounting location where air line 

 

  can be routed from compressor air inlet to remote inlet air filter.  Make sure that the remote inlet air 

 

  filter is located in a dry location, away from the elements.  

6. You will also want to select a compressor mounting location where the leader hose bracket can be 

 

  mounted to leader hose.

7. If it is necessary to mount the air compressor further away from the battery, such as inside 

 

  your vehicle or in the bed of your pickup, use a positive lead wire for remote installation. Refer to  

  the wire gauge guide on the back of this manual.

8. Do not mount compressor near areas where flammable liquids are stored.

9. Use thread sealant for proper fitting installation. Thread tape is not recommended. 

  Properly sealed, recommended torque is 12 to 15 ft. lbs

USER MANUAL

425C COMPRESSOR KIT 

Содержание 425C

Страница 1: ......

Страница 2: ...hicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please pay close attention to th...

Страница 3: ...on 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor s positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 13 Always locate fuse as close...

Страница 4: ...ep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas 7 The use of a relay is strongly recommended for installation of this compressor but not included 40 amp relay value or higher per compressor recommended MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mo...

Страница 5: ...ent Consumption 30 amps Motor Type Permanent Magnetic Horsepower 1 4 Max Working Pressure 175 PSI Max Duty Cycle 72ºF 100 PSI 50 Minutes On Off 72ºF 100 PSI 30 On 30 Off Max Restart Pressure 175 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes USER MANUAL 425C COMPRESSOR KIT ...

Страница 6: ...e refers to the amount of time a compressor can be operated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off 15 9 Min On 51 Min Off 20 12 Min On 48 Min Off 25 15 Min On 45 Min Of...

Страница 7: ...uently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressor co...

Страница 8: ...RS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval system communicated or transmitted by any means for any commercial purpose including without limitat...

Отзывы: