background image

SAFETY PRECAUTIONS:

1. Always inflate tires to manufacturer’s recommended tire pressures. Exercise extreme caution 

  when driving with aired-down tires. Reinflate tires before high-speed roadway travel.

2. Never exceed 20 M.P.H. when driving with partially inflated tires.

3. Never make sharp turns while driving with reduced tire pressure.

4. Re-inflate tires before high speed traveling onto roadways.

5. Use heat-resistant, minimum 200 PSI-rated working pressure extension hose. 

  Do not use aftermarket hoses with less than 200 PSI working pressure. 

  Some aftermarket hoses may not be suitable for use with this air compressor due to heat and  

  pressure typically generated by this type of air compressors.

6. The use of a close-ended tire chuck will cause excessive pressure buildup if tire chuck is not

  attached to tire valve stem while air compressor is in operation.

IMPORTANT: Always use an Open-Ended tire chuck such as the tire chuck equipped on the 

Deflator/Inflator Coil Hose for tire inflation when using a compressor without an air tank.

CAUTION: The extension hose and fittings connected extension hose will become very HOT during 

and after use. If necessary, wear heat resistant gloves to remove hose from the compressor quick 

connect stud.

MAINTENANCE & REPAIRS:

Your air compressor is equipped with permanently lubricated, maintenance-free motor. Never try 

to lubricate the compressor.  Regularly clean dust and dirt from compressor cooling fins and motor 

housing.   All repairs should be performed by Manufacturer or Manufacturer authorized service 

agencies only.

MODEL 400P SPECIFICATIONS:

Part Number:   

40043 / 400P   

Motor Voltage:  

12-volt

Motor Type:  

Permanent Magnetic

Max. Intermittent Pressure:  

150 PSI

Max. Duty Cycle:  

33% (15 on / 30 off)

(Min. On/Off @ 72ºF & 100 PSI)

Continuous Use @ 72ºF & 30 PSI:  

Approx. 40 Minutes

Max. Current Consumption:  

30 Amps

Fuse:  

40 Amps

Inline Pressure Gauge:  

160 PSI

Auto. Reset Thermal Protection:  

Yes

400P PORTABLE COMPRESSOR

LIMITED WARRANTY:

VIAIR Corporation warrants this product, when properly installed 

and under normal conditions of use, to be free from defects in 

workmanship and materials for a period of one year from its 

original date of purchase. To receive warranty service or repair, 

please contact VIAIR Corporation.  

Returns should be made within one year of the date of purchase, 

after a Return Goods Authorization (RGA) number has been 

assigned by VIAIR Corporation.  To obtain RGA, fax a copy of 

your receipt to (949) 585-0188. For complete warranty details, 

please visit: 

www.viaircorp.com/warranty

PLEASE NOTE: THIS WARRANTY COVERS PRODUCT DEFECTS 

ONLY; IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL 

DAMAGES AS RESULT OF MISUSE OR ABUSE. 

15 EDELMAN • IRVINE, CA 92618

TEL: (949) 585-0011

FAX: (949) 585-0188

www.viaircorp.com 

Содержание 40043

Страница 1: ... and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 400P PORTABLE COMPRESSOR HEAVYWEIGHT SERIES PART NO 40043 ...

Страница 2: ...nce and best use out of your air compressor 1 Always operate the compressor AT OR BELOW THE MAXIMUM PRESSURE RATING of the compressor Refer to Specifications section of this manual 2 Always OBSERVE THE MAXIMUM DUTY CYCLE of the air compressor Refer to Specifications section of this manual for details Operations exceeding maximum pressure ratings and or duty cycle will result in damage to air compr...

Страница 3: ...sor switch on to begin inflation When desired pressure is reached turn compressor off CAUTION To avoid over inflation never exceed recommended pressure on articles to be inflated Bursting can cause serious injury HANDS FREE CONTINUOUS DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock ...

Страница 4: ...r air compressor is equipped with permanently lubricated maintenance free motor Never try to lubricate the compressor Regularly clean dust and dirt from compressor cooling fins and motor housing All repairs should be performed by Manufacturer or Manufacturer authorized service agencies only MODEL 400P SPECIFICATIONS Part Number 40043 400P Motor Voltage 12 volt Motor Type Permanent Magnetic Max Int...

Отзывы: