MOUNTING AND WIRING

1.  Disconnect ground cable from vehicle’s battery.

2.   Temporarily position the air compressor in the location where it will be mounted.  

3.   Route ground wire to the negative post of the battery or to an appropriate grounding point and  

 

cut ground wire to length as needed. 

4.   Mount air compressor with the four sets of bolts, nuts, washers, and locking washers provided.  

 

(See Fig. 2 for Mounting Instructions) Use of thread sealant is recommended.

5.  

NOTE: For Remote Inlet Air Filter Installation, refer to Remote Inlet Air Filter Installation  

 

Instruction included in the Remote Inlet Air Filter Pack. 

6.   VIAIR air compressor(s) come equipped with heavy duty heat resistant leader hose(s) with 

 

either  1/4” or 3/8” NPT fittings.  This leader hose is designed to prolong the life of your air line.  

 

Do not remove this leader hose from air compressor.

7.

   IMPORTANT: Please note, the leader hose that comes with your compressor has a built-in inline  

 

check valve.  Do Not remove inline check valve from leader hose.    

8.   Select proper location to mount leader hose with hose bracket provided.  Avoid locations where  

 

leader hose may become tangled with wires and other hoses.  

9.   To mount hose bracket, drill hole with 3/16” drill bit and push self–anchoring hose bracket pin  

 

into hole.  Route leader hose through hose bracket and secure hose by pressing bracket clamp  

 

into locked position.  

10. To remove hose from the hose bracket, simply press down on the hose clamp release tab to  

 

release bracket clamp. (Fig. 3)

11. Connect compressor’s positive lead wire to one of the leads of your pressure switch.  

12. Make sure that your compressor setup is properly fused.  For appropriate fuse size, refer to 

 

amp draw of compressor in the specifications section of this manual.  

13. Always locate fuse as close as possible to power source.  

14. Before connecting to power source, re-check to make sure that all connections are 

 

made properly.  

15. Connect and test compressor system by running the compressor for a short time to build up  

 

pressure in your air tank.  

16. Once air pressure reaches preset cut out pressure of your pressure switch, the compressor 

 

will shut off.   Inspect all air line connections for leaks with soap and water solution.  If a leak 

 

is detected, the air line may not be cut squarely or pushed all the way in.  Repair connections 

 

as needed. 

 

(Fig. 1) 380C / 480C Compressor Installation Parts List: 

 

A.  Hose Bracket (1pc)

B.  Mounting Bolts (4pcs)

C. Flat Washers (8pcs)

D.  Locking Washers (4pcs)

E.  Nuts (4pcs)

F.   3/8NPT F x 1/2” Barbed Fitting  (1pc)  (480C)

     1/4NPT F x 1/2” Barbed Fitting (1pc) (380C)

G.  3/8NPT M x 1/2” Barbed Fitting (1pc)  (480C)

     1/4NPT M x 1/2” Barbed Fitting (1pc) (380C)

H. Remote Mount Filter Air Line (1pc) (380C)

I.   Air Line Clips (3pcs)      

J.  Screws (3pcs)

K.  Remote Inlet Air Filter with Filter Element (1pc)

USER MANUAL

380C - 480C COMPRESSOR KIT 

C

E

B

A

D

F

G

I

J

K

H

Содержание 380C

Страница 1: ...T NO 48043 200 PSI COMPRESSORS MODEL NUMBERS IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 380C 480C ...

Страница 2: ... injury or damage to the compressor or your vehicle Each of our air compressors and parts have been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service l...

Страница 3: ...et and secure hose by pressing bracket clamp into locked position 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor s positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the speci...

Страница 4: ...e s engine running while using the air compressor 6 ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS 7 Compressor performance is enhanced when operating compressor with vehicle s engine running MAINTENANCE REPAIRS 1 Periodically check all electrical fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace Air Filter Element perio...

Страница 5: ...0ºF Auto Reset Thermal Protection Yes Dimensions 9 L x 4 W x 6 75 H Net Weight 8 75 Lbs Part No 48043 480C Air Compressor CE Spec Motor Voltage 12 Volts Max Current Consumption 20 Amps Motor Type Permanent Magnetic Horsepower 1 4 Max Working Pressure 200 PSI Max Duty Cycle 72ºF 100 200 PSI 100 50 Minutes On Off 72ºF 100 PSI Continuous Max Ambient Temperature 158ºF Min Ambient Temperature 58ºF Auto...

Страница 6: ... Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 Minutes ON and 30 Minutes OFF 10 Min On 10 Min On 30 Min Off 10 Min 40 Min 25 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 720 F MINUTES ON OFF 15 6 Min On 34 Min Off 20 8 Min On 32 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min O...

Страница 7: ...equently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressor ...

Страница 8: ... purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain an RGA number fax a copy of your receipt to 949 585 0188 For complete warranty details visit www viaircorp com warranty IMPORTANT THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE VIAIR CORPORATION 15 EDELMAN IRVINE CA 9...