TROUBLESHOOTING GUIDE:

Tank pressure drops when 

compressor (s) shut off

1. Loose drain cock

2. Check valve leaking

3. Loose connections

1. Tighten drain cock

2. Replace check valve or

 compressor(s)

3. Check all connections with

 soap and water solution 

 and tighten

Compressor runs 

continuously and air flow 

lower than normal

1. Excessive air usage

2. Loose connections

3. Worn piston ring or inlet

 valve.

4. Clogged air filter element 

1. Decrease air usage

2. Check all connections with

 soap and water solution 

 and tighten.

3. Repair or replace compressor

4. Replace air filter element 

Compressor runs 

continuously causing 

safety valve (if equipped) 

to open

1. Bad pressure switch

2. Defective safety valve

1. Replace pressure switch

2. Replace safety valve

Excessive moisture 

in discharge

1. Excessive water in air tank

2. High humidity

1. Drain tank, tilt tank to drain.

  Drain tank more frequently

2. Move compressor to area

 with less humidity, or use air 

 line filter.

Compressor will not run

1. No power, or power switch

 in OFF position

2. Blown fuse

3. Motor overheats

4. Faulty pressure switch. 

1. Make sure compressor

 switch is ON 

2. Disconnect compressors

 from power source, replace 

 fuse. (Refer to Specifications 

 section for correct fuse 

 amperage.)

3. Let compressors cool off for

 about 30 Minutes to allow 

 thermal overload switch reset.

4. Replace pressure switch

Thermal overload 

protector cuts 

out repeatedly

1. Lack of proper ventilation or

 ambient temperature too high

2. Compressor valves failed

1. Move compressor to well

 ventilated area, or area with 

 lower ambient temperature

2. Repair or replace compressor

Excessive knocking 

or rattling

1. Loose mounting bolts

2. Worn bearing on eccentric or

 motor shaft

3. Cylinder or piston ring is worn

1. Tighten mounting bolts

2. Repair or replace compressor

3. Repair or replace compressor 

CAUTION: NEVER DISASSEMBLE COMPRESSOR WHILE 

COMPRESSOR IS PRESSURIZED.

USER MANUAL

330C-HG - 200PSI COMPRESSOR KIT

Содержание 330C-HG

Страница 1: ......

Страница 2: ... carefully to avoid injury or damage to the compressor and your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service ...

Страница 3: ...our pressure switch 10 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 11 Always locate fuse as close as possible to power source 12 Before connecting to power source re check to make sure that all connections are made properly 13 Connect and test compressor system by running the compresso...

Страница 4: ...d for installation of this compressor 40 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment we rec...

Страница 5: ...USER MANUAL 330C HG 200PSI COMPRESSOR KIT ...

Страница 6: ...85 SERIES 200 PSI 100 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off...

Страница 7: ...ank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30...

Страница 8: ...eceipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted...

Отзывы: