VIAIR 28021 Скачать руководство пользователя страница 6

USER MANUAL

280C Air Compressor Kit

COMPRESSOR APPLICATION GUIDE

To ensure that you get the highest level of satisfaction from your compressor performance, refer to 

information below: 

VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES 

DUTY CYCLE 

WORKING PRESSURE

100 SERIES 

 

15% 

 

130 PSI

215 SERIES 

 

17% 

 

150 PSI

225 SERIES 

 

20% 

 

150 PSI

265 SERIES 

 

22% 

 

150 PSI

275 SERIES 

 

25% 

 

150 PSI

300 SERIES 

 

30% 

 

150 PSI

400 SERIES 

 

33% 

 

150 PSI

450 SERIES 

 

100% 

 

150 PSI

500 SERIES 

 

33%  

 

150 PSI 

550 SERIES 

 

100%  

 

150 PSI 

ABOUT COMPRESSOR DUTY CYCLE:

Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time 

period, at 100 PSI & at a standard ambient temperature of 72°F. 

Duty Cycle is commonly expressed as:

Compressor On Time / (Compressor On Time + Off Time)

As an example, a compressor that is rated for 20% duty cycle means that compressor can be 

operated at 100 PSI @ 72°F for 8 Minutes and rested for 32 Minutes.

8 min. on / (8 min. on + 32 min. off) = 20% Duty Cycle

DUTY CYCLE REFERENCE CHART

DUTY CYCLE @100PSI / 72°F  

MINUTES ON / OFF

15% 

 

 

 

6 Min. On / 34 Min. Off

17% 

 

 

 

7 Min. On / 30 Min. Off

20% 

 

 

 

8 Min. On / 32 Min. Off

22% 

 

 

 

9 Min. On / 30 Min. Off

25% 

 

 

 

10 Min. On / 30 Min. Off 

30% 

 

 

 

13 Min. On / 30 Min. Off

33% 

 

 

 

15 Min. On / 30 Min. Off

100% 

 

 

 

Continuous Duty

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated 

working pressure of the compressor.  Never use a pressure switch with a higher cut-off pressure 

than compressor’s rated working pressure. 

Содержание 28021

Страница 1: ...l that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL PART NO 28021 280C AIR COMPRESSOR KIT ...

Страница 2: ...refully to avoid injury or damage to the compressor or your vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble...

Страница 3: ...lamp into locked position 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the Specifications section of this manual 13 Always...

Страница 4: ... enhance performance keep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas 7 The use of a relay is strongly recommended for installation of this compressor but is not included 40 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fitting connections Clean and tighten as needed 2 Periodically check all moun...

Страница 5: ...or Type Perm Magnetic Horse Power 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72ºF 100 PSI 30 Minutes On Off 72ºF 100 PSI 13 On 30 Off Max Restart Pressure 200 PSI Max Ambient Temperature 158ºF Min Ambient Temperature 40ºF Auto Reset Thermal Protection Yes Dimensions 7 1 L x 3 9 W x 6 3 H Net Weight 6 95 Lbs USER MANUAL 280C Air Compressor Kit ...

Страница 6: ... a standard ambient temperature of 72 F Duty Cycle is commonly expressed as Compressor On Time Compressor On Time Off Time As an example a compressor that is rated for 20 duty cycle means that compressor can be operated at 100 PSI 72 F for 8 Minutes and rested for 32 Minutes 8 min on 8 min on 32 min off 20 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 72 F MINUTES ON OFF 15 6 Min On 34 M...

Страница 7: ...r to area with less humidity or use water separator Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30 mi...

Страница 8: ... 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE WIRE GAUGE GUIDE 12 VOLT Amp Draw Length of wire from battery to compressor 10 15 20 25 30 10 14 12 10 10 10 15 12 10 10 8 8 20 10 10 8 6 6 25 10 8 6 6 6 30 10 8 6 6 4 40 8 6 6 4 4 50 6 6...

Отзывы: