TROUBLESHOOTING GUIDE:

Tank pressure drops when 

compressor(s) shut off

1. Loose drain cock

2. Check valve leaking

3. Loose connections

1. Tighten drain cock

2. Replace check valve or

  compressor

3. Check all connections with

  soap and water solution  

  and tighten

Compressor runs 

continuously and air flow 

lower than normal

1. Excessive air usage

2. Loose connections

3. Worn piston ring or inlet valve.

4. Clogged air filter element 

1. Decrease air usage

2. Check all connections with

  soap and water solution 

  and tighten.

3. Replace compressor

4. Replace air filter element 

Compressor runs 

continuously causing 

safety valve (if equipped) 

to open

1. Faulty pressure switch

2. Defective safety valve

1. Replace pressure switch

2. Replace safety valve

Excessive moisture 

in discharge

1. Excessive water in air tank

2. High humidity

1. Drain tank, tilt tank to drain.

 Drain tank more frequently

2. Move compressor to area

 with less humidity, or use 

 water separator

Compressor will not run

1. No power, or power switch

  in OFF position

2. Blown fuse

3. Motor overheats

4. Faulty pressure switch  

    (if hooked up to a  

    pressure switch).

1. Make sure compressor

 switch is ON   

2. Disconnect compressor

 from power source, replace 

 fuse.  (Refer to Specifications 

 section for correct 

 fuse amperage)

3. Let compressors cool off for

 about 30 minutes to allow 

 thermal overload switch to reset.

4. Replace pressure switch

Thermal overload 

protector cuts out 

repeatedly

1. Lack of proper ventilation or

 ambient temperature is too high

2. Compressor valves failed

1. Move compressor to well

 ventilated area, or area with 

 lower ambient temperature

2. Replace compressor

Excessive knocking 

or rattling

1. Loose mounting bolts

2. Worn bearing on eccentric or

 motor shaft

3. Cylinder or piston ring is worn

1. Tighten bolts

2. Replace bearing or 

    piston assembly

3. Replace piston or compressor 

CAUTION:  NEVER DISASSEMBLE COMPRESSOR WHILE 

COMPRESSOR IS PRESSURIZED.

USER MANUAL

100C Air Compressor Kit

PROBLEM:

POSSIBLE CAUSE(S) 

CORRECTIVE ACTION 

Содержание 100C

Страница 1: ... MANUAL 10010 100C Air Compressor standard mounting bracket CE Certified 10014 100C Air Compressor no leader hose or check valve CE Certified 10016 100C Air Compressor with Omega Bracket CE Certified 10019 100C Air Compressor Stealth Black with Omega Bracket CE Certified 100C Air Compressor Kit 100C P N 10014 100C P N 10016 100C P N 10019 Stealth Black 100C P N 10010 P N 10010 P N 10010 10014 1001...

Страница 2: ...ur vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please pay close attention ...

Страница 3: ...et clamp into locked position 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the Specifications section of this manual 13 Al...

Страница 4: ...r will automatically cut power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart the air compressor Turn off power and allow unit to cool for about 30 minutes This will allow the Thermal Overload Protector to reset so...

Страница 5: ...to the air compressor with bare hands during or immediately after use Leader hose and fittings connected to Leader Hose will become very hot during and after use If necessary wear heat resistant gloves to handle fittings air line and leader hose SPECIFICATIONS 100C AIR COMPRESSOR PART NUMBERS Part No 10010 100C Air Compressor standard mounting bracket CE Certified Part No 10014 100C Air Compressor...

Страница 6: ...PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off 15 9 Min On 51 Min Off 20 12 ...

Страница 7: ...r to area with less humidity or use water separator Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30 mi...

Страница 8: ...omplete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval syste...

Отзывы: