27
Fig.
№
. 21 Cleaning of the smoke extension piece
3.5
IMPORTANT NOTICE
1.
The boiler only can be used for the purpose that it is destined for.
2.
The boiler can be operated only by adult persons acquainted with this operation manual. It is
inadmissible to leave the children unattended by adults near the boiler. The boiler construction
intervention, which can endanger the attendant´s safety, eventually the housemate´s safety, is
inadmissible.
3.
The boiler is not destined for the use by persons (incl. children) whose physical, sensual or mental
disability or lack of experience and knowledge prevent them from a safe use of the appliance unless
they are supervised or if they were not instructed on the use of appliance by a person responsible for
their safety.
4.
Children should be supervised in order to ensure that they do not play with the appliance.
5.
If there occurs a danger or flammable vapours and gases development and penetration into the boiler
room, or at works accompanied by the temporary development of the fire or explosion (gluing the floor
covering, painting with combustible painting colours), the boiler must be duly closed down before the
works start.
6.
It is FORBIDDEN to use the flammable liquids for boiler firing.
7.
It is FORBIDDEN to overheat the boiler during its operation. Fill the boiler under the lower edge of
stoking door. Open the stoking door by use of plastic handle and half-open the ash door to smoke
vent the smoke gases.
8.
It is forbidden to put the flammable materials on the boiler or in its near distance.
9.
When cleaning the ashes at boiler there must not be put any flammable materials within minimally
1500 mm distance from the boiler.
10. When operating the boiler at the temperature lower than 60 C the boiler drum can be bedewed, which
means the low-temperature corrosion and reduction of boiler drum service life. Therefore we
recommend to operate the boiler at the temperature of 60 C and higher. Possible corrosion marks on
boiler drum don´t mean a defect and they don´t affect the boiler function.
11. In case of a storage container usage, the boiler can be fired or stoked up again, if the boiler is burned
down to the fire basis, and the storage container is empty or cool.
ATTENTION! Ignoring leads to extreme heat exchanger fouling.
1
Insulation of the cleaning covering of the
smoke extension part
2
Cleaning covering of the smoke extension
piece
3
Washer 5,3
4